Fig. 4: Overview measurement ranges, Bipolar
Fig. 5: Overview measurement ranges, Unipolar
Note: In Extended Range Mode the Underrange/Overrange display in the PDO status has the character of an information/warning
when the nominal measuring range is exceeded, i.e. no Error is displayed in the PDO status and LED. If the technical measuring range
is also exceeded, Error = TRUE is also displayed. The detection limit for Underrange/Overrange Error can be set in the CoE.
In Legacy Range mode, an Underrange/Overrange event also leads to an Error in the PDO status.
EPP3504-0023
Version: 1.2
Product overview
19