Modification To Toll Restriction Service - Panasonic VB-44210G User Manual

Digital business system
Table of Contents

Advertisement

Appendix B. CPC-AII/B 8.0 Feature Update
Programming
Operation

Modification to Toll Restriction Service

Description
Programming
Notes
Page B-20
See Section 400 - Programming (Appendix D) for more detailed
programming information.
The 44-Series EM/24 operates the same as previous models.
The program address for TRS Operator Access (FF7 1# 18#...) has been
modified to allow an extension to dial "0+NXX" phone numbers, even if
"0-only" dialing is denied.
Four settings are possible.
See Section 400 - Programming (Appendix D) for more detailed
programming information.
• The Operator Access address applies only to DBS systems using the
(1995) NANP dialing plan (FF7 1# 17# 1#), and to TRS types 2-6 (TRS
types 0 and 1 do not allow outbound dialing; TRS type 7 allows all
dialing).
• If "0-only", "00-only", "10XXX0-only", or "101XXXX0-only" calls
are restricted (settings 0 or 2), the system will wait 6 seconds before
automatically disconnecting the call. However, if the user dials
additional digits within 6 seconds, the DBS will check other switches to
determine whether to allow or deny the call.
• For all settings (0-3), the system will check the Equal Access Code
Format switch (FF7 1# 21#...) if a CIC (carrier identification code) is
dialed to reach a preferred inter-exchange carrier.
• For all settings (0-3), the system will check the international calls
switches (FF7 1# 1# and FF7 1# 19#) if "01", "10XXX01", or
"10XXXX01" is dialed.
• For settings 2 and 3, the system will not consider TRS settings for the
trunk.