158813-1CD
MH80 Manipulator
9
Maintenance and Inspection
9.3 Notes on Grease Replenishment/Exchange Procedures
7. Wipe the discharged grease with a cloth and reinstall the plug PT1/8
on the grease exhaust port. Apply Three Bond 1206C to the thread
part of the plug, and tighten the plug with a tightening torque of
·
·
4.9 N
m (0.5 kgf
m).
If the plug is installed while the grease is being exhausted,
the grease will go inside the motor and may cause a
NOTE
damage. Ensure that the grease has been completely
exhausted before installing the plug.
8. Remove the grease zerk from the grease inlet and reinstall the plug
PT1/8. Apply Three Bond 1206C to the thread part of the plug, and
tighten the plug with a tightening torque of 4.9 N
9-15
·
·
m (0.5 kgf
m).
57 of 77
HW1480080