<Client Setting>
• To set whether or not to encrypt communication.
<Heart Beat>
NOTE
▪ The heat beat function is only available to http1.
• To make Heart Beat related settings.
• Heart Beat is a feature that uploads a Heart Beat file to the registered web server at a specified interval to report that the device is
operating. Heart Beat files include total counter and status information.
<Polling Interval>
NOTE
▪ The polling interval function is only available to http1.
• To set the polling time in http communication.
<Initial Transmission>
• Touching the Initial Transmission key will sent the information to the CS Remote Care center to register the machine.
(3)  Date & Time Setting
(a)  Use
• To set the data and time-of-day.
(b)  Procedure
1. Call the Service Mode to the screen.
2. Touch [CS Remote Care] -> [Maintenance/Default Settings].
3. Touch [Detail Setting] to access Date & Time Setting.
4. Enter the date (month, day and year), time-of-day, and the time zone from the 10-key pad.
5. Touch [SET] to start the clock.
(4)  RAM Clear
(a)  Use
• To clear the following data at the center.
Service ID, Basic setting, Date & time setting (time zone), Software SW setting, AT command
• To be used for setting CS Remote Care.
• To be used for reset the every data of the center to default.
NOTE
▪ If RAM clear is selected during transmission, RAM clear processing will be implemented at the time the transmission is
completed regardless of whether it is done properly or not.
(b)  Default setting
• Unset
(c)  Setting item
• Set
• Unset
(5)  Communication Log Print
(a)  Use
• To print out the communication log.
(b)  Procedure
1. Call the Service Mode to the screen.
2. Touch [CS Remote Care] -> [Maintenance/Default Settings].
3. Touch [Detail Setting] to access communication log print.
4. Load a paper tray with A4S/A4 or 81/2 x 11S/81/2 x 11 paper.
5. Select [1-Sided] or [2-Sided].
6. Press Start key to print out the communication log.
(6)  Software Switch Setting
(a)  Use
• To change the CS Remote Care settings.
(b)  Procedure
• Refer to "
I.5.9 Software SW setting for CS Remote
(7)  Response Time Out
(a)  Use
• It sets the intervals for resending e-mails when transmission error occurred.
• It can be set only when [E-Mail] is selected in [System Setting].
(b)  Default setting
• 60 minutes
Care" for the setting.