(e)  Note on returning the setting from "Controller 1" to "Controller 0".
• Selecting "Controller 0" will initialize the following settings made while "Controller 1" was selected. Reset the following items as
necessary when using the internal standard controller.
<Control panel on the machine>
• Setting items included in [Network Setting] available from [Administrator Setting]. (Except [Status Notification Setting] and [Prefix/Suffix
Setting] available from the following setting. [Administrator Settings] -> [Network Settings] -> [Detail Settings].)
• [Administrator Settings] -> [User Authentication /Account Track] -> [General Settings] -> [User Authentication] -> [External Server
Authentication]
• [Administrator Settings] -> [System Connection] -> [OpenAPI Settings]
• Mailbox Destination (scan)
• Information on the original specified by the program destination
<Page Scope Web Connection>
• SSL/TLS
(2)  Peripheral Mode
(a)  Procedure
• Select the operating mode of the Scanner.
NOTE
▪ After changing setting, make sure to turn off the main power switch and turn it on again more than 10 seconds after.
(b)  Functions
• Mode 1: undefined.
• Mode 2: undefined.
• Mode 3: undefined.
5.16.3  Option Board Status
(1)  Use
• To be used for setup of the optional fax kit (FK-514*1, FK-515*2) or the security kit (SC-508).
NOTE
▪ *1: FK-514 is used for FAX line 1/line 2.
▪ *2: FK-515 is used for FAX line 3/line 4. The Fax Mount kit (MK-742) is required when line 3/4 is installed.
(2)  Default setting
• Unset
(3)  Setting item
FAX (circuit 1)
• Set
• Unset
FAX (circuit 2)
• Set
• Unset
FAX (circuit 3)
• Set
• Unset
FAX (circuit 4)
• Set
• Unset
DSC1
• Set
• Unset
DSC2
• Set
• Unset
NOTE
▪ When the setting has been changed, turn off the main power switch and turn it on again more than 10 seconds after.
5.16.4  Consumable Life Reminder
(1)  Use
• To select whether or not to give the display of PM parts lifetime
PM parts lifetime display
• Applicable units:
Transfer belt unit, fusing unit, developing unit, drum unit, transfer roller unit
• Use to select not to give the display of PM parts lifetime.
Yes
No
(2)  Default setting
• No
An entire screen warning is given when the service life of a specific unit has been reached,
prompting the user to replace the part.
When the service life has been reached, a malfunction code and an entire screen warning appear on the control
panel.
When the service life has been reached, a malfunction code and a message appear in one line on the upper