bizhub C658/C558/C458/C368/C308/C258
(3) Setting item
• Type 1
• Type2
5.15.15 TP Level
(1) Use
• To adjust the selectivity of the touch panel.
(2) Default setting
• 0
(3) Setting range
• -2 to +2 (step: 1*)
• To increase sensitivity of the touch panel, increase the setting value.
• To decrease sensitivity of the touch panel, decrease the setting value.
NOTE
▪ When the setting has been changed, turn off the main power switch and turn it on again more than 10 seconds after.
5.15.16 Burn Prevention Settings
(1) Use
• To prompt to prevent a burn injury by displaying a message indicating that the fusing unit is at a high temperature when the right door
has to be opened in order to get rid of a paper jam.
(2) Default setting
• Enable
(3) Setting item
• Enable
• Disable
5.16 System 2
I ADJUSTMENT/SETTING > 5. SERVICE MODE
I-143