# Save the running configuration to the main next-startup configuration file without any confirmation
required.
<Sysname> save force
Validating file. Please wait....
Saved the current configuration to mainboard device successfully.
# Save the running configuration to a file in the root directory of the default storage medium, and
specify the file as the main next-startup configuration file.
<Sysname> save
The current configuration will be written to the device. Are you sure? [Y/N]:y
Please input the file name(*.cfg)[flash:/backup.cfg]
(To leave the existing filename unchanged, press the enter key):test.cfg
Validating file. Please wait............
Saved the current configuration to mainboard device successfully.
Related commands
display current-configuration
display saved-configuration

standby auto-update config

Use
standby
configuration file operations.
Use
undo standby auto-update config
configuration file operations.
Syntax
standby auto-update config
undo standby auto-update config
Default
Next-startup configuration file operations are automatically synchronized across the entire system.
Views
System view
Predefined user roles
network-admin
Usage guidelines
By default, automatic system-wide next-startup configuration file operations are enabled. The
system performs the following operations on all IRF subordinate devices in addition to the master
device:
Saves the running configuration to the next-startup configuration file on each member device
when you execute the
command.
Deletes the next-startup configuration file on each member device when you execute the
reset saved-configuration
If you disable automatic system-wide next-startup configuration file operations, the system saves the
running configuration or deletes the next-startup configuration file only on the master device.
Automatic system-wide operations ensure start-up configuration file consistency between the master
and subordinate devices. However, a system-wide operation takes more time than an operation
auto-update
config
save [ safely ] [ backup | main ] [ force ] [ changed ]
to enable automatic system-wide next-startup
to disable automatic system-wide next-startup
command.