Summary of Contents for H3C H3C S5510 Series

  • Page 1 H3C S5510 Series Ethernet Switches Installation Manual Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Manual Version: T2-20080228-C-1.05...
  • Page 2 Copyright © 2006-2008, Hangzhou H3C Technologies Co., Ltd. and its licensors All Rights Reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd.
  • Page 3: About This Manual

    About This Manual Related Documentation In addition to this manual, each H3C S5510 Series Ethernet Switches documentation set includes the following: Manual Description H3C S3610&S5510 Series Ethernet It is used for assisting the users in data Switches Operation Manual configurations and typical applications.
  • Page 4 Conventions The manual uses the following conventions: I. Command conventions Convention Description Boldface The keywords of a command line are in Boldface. italic Command arguments are in italic. Items (keywords or arguments) in square brackets [ ] are optional. Alternative items are grouped in braces and separated by { x | y | ...
  • Page 5 Environmental Protection This product has been designed to comply with the requirements on environmental protection. For the proper storage, use and disposal of this product, national laws and regulations must be observed.
  • Page 6: Table Of Contents

    Installation Manual H3C S5510 Series Ethernet Switches Table of Contents Table of Contents Chapter 1 Product Overview ......................1-1 1.1 Introduction ........................1-1 1.2 S5510-24P-AC/S5510-24P-DC Ethernet Switch............... 1-2 1.2.1 Front Panel......................1-2 1.2.2 Rear Panel ......................1-9 1.3 S5510-24F-AC/S5510-24F-DC Ethernet Switch ............. 1-10 1.3.1 Front Panel......................
  • Page 7 Installation Manual H3C S5510 Series Ethernet Switches Table of Contents 4.3 Setting Terminal Parameters ..................... 4-1 4.4 Booting the Switch ......................4-4 4.4.1 Verifying Installation before Power-up ..............4-4 4.4.2 Powering up the Switch................... 4-4 Chapter 5 Loading Boot ROM and Host Software ..............5-1 5.1 Introduction to Loading Approaches ..................
  • Page 8: Chapter 1 Product Overview

    Chapter 1 Product Overview 1.1 Introduction H3C S5510 Series Ethernet Switches (hereinafter referred to as S5510 series) are wire speed Layer 2/3 Ethernet switches developed by Hangzhou H3C Technologies Co., Ltd. They are intelligent network-manageable switches intended for network environments requiring high performance, dense port distribution, and ease of installation.
  • Page 9: S5510-24P-Ac/S5510-24P-Dc Ethernet Switch

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview 1.2 S5510-24P-AC/S5510-24P-DC Ethernet Switch 1.2.1 Front Panel I. Illustration The S5510-24P-AC and S5510-24P-DC have the same front panel. On the front panel, S5510-24P-AC/S5510-24P-DC provides fixed 10/100/1000Base-T auto-negotiation Ethernet ports, four 1000 Mbps Combo SFP ports and one Console port, as shown in Figure 1-1.
  • Page 10 Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview one port mode switch LED, one 7-segment numerical display LED, 24 x 10/100/1000 Mbps Ethernet port status LEDs, four Combo SFP port status LEDs on its front panel. Table 1-3 describes the meanings of these LEDs:...
  • Page 11 Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview Mark Status Meaning Solid green The switch works normally. The switch is running power-on self-test (POST) or is loading software. (1) When running POST, The system displays the number of current POST...
  • Page 12 Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview Mark Status Meaning The power slot 1 accommodates a power Solid green module, which is working normally. The power slot 1 accommodates a power Solid yellow module, which is not used Power module 1 now.
  • Page 13 Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview Mark Status Meaning The number of current In the process of POST item is displayed. POST The number of the failed POST item is displayed. POST failure 7-segment The short bars are lighted...
  • Page 14 Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview Mark Status Meaning The port works at 1000 Mbps; when it Green receives/sends data, the LED flashes quickly. In speed mode Flashing yellow The port fails the POST. (at 3 Hz) The port is disconnected.
  • Page 15 SFP-GE-T Note: The types of SFP modules may vary over time. Consult H3C marketing personnel or technical support personnel to obtain the latest information about SFP modules. For specifications of SFP modules, refer to H3C Low End Series Ethernet Switches Pluggable Module Manual.
  • Page 16: Rear Panel

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview Item Description Connection with a character terminal Connection with the serial interface of a local terminal (a PC for Service example) or a remote terminal (through a pair of modems), on which a terminal emulation program is running 1.2.2 Rear Panel...
  • Page 17: S5510-24F-Ac/S5510-24F-Dc Ethernet Switch

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview IV. DC-input voltage range Rated voltage range: –48 VDC to –60 VDC Rated voltage range: –36 VDC to –72 VDC 1.3 S5510-24F-AC/S5510-24F-DC Ethernet Switch 1.3.1 Front Panel I. Illustration The S5510-24F-AC and S5510-24F-DC have the same front panel.
  • Page 18 Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview one 7-segment numerical display LED, 24 SFP port status LEDs, four 10/100/1000 Mbps Combo port status LEDs on its front panel. Table 1-8 describes the meanings of these LEDs:...
  • Page 19 Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview Mark Status Meaning The power slot 1 accommodates a power Solid green module, which is working normally. The power slot 1 accommodates a power Solid yellow module, which is not used Power module 1 now.
  • Page 20 Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview Mark Status Meaning The number of current POST In the process of item is displayed. POST The number of the failed POST item is displayed. Post failure 7-segment numerical...
  • Page 21 Table 1-5. Note: The types of SFP modules may vary over time. Consult H3C marketing personnel or technical support personnel to obtain the latest information about SFP modules. For specifications of SFP modules, refer to H3C Low End Series Ethernet Switches Pluggable Module Manual.
  • Page 22: Rear Panel

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview 1.3.2 Rear Panel I. Rear panel Illustration of the S5510-24F-AC As shown in Figure 1-5, the S5510-24F-AC provides a power module handle, power fan, cable clip, AC-input power socket, dummy panel and grounding screw (from left to right) on its rear panel.
  • Page 23: Technical Specifications Of S5510 Series

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 1 Product Overview 1.4 Technical Specifications of S5510 Series Table 1-10 Technical specifications of S5510 series Item S5510-24P S5510-24F Physical dimensions 43.6 x 440 x 360 mm (1.7 x 17.3 x 14.2 in.)
  • Page 24: Chapter 2 Installation Preparation

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 2 Installation Preparation Chapter 2 Installation Preparation 2.1 Safety Precautions To avoid any device impairment and bodily injury caused by improper use, observe these rules: Before cleaning the switch, unplug the power plug of the switch first. Do not clean the switch with wet cloth or liquid.
  • Page 25: Cleanness

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 2 Installation Preparation For the temperature and humidity requirements of different models, refer to section 1.4 Technical Specifications of S5510 Series. 2.2.2 Cleanness Dust is a hazard to the operating safety of your device. The dust accumulated on the chassis can be adsorbed by static electricity and result in poor contact of metal connectors or metal contact points.
  • Page 26: Laser Safety

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 2 Installation Preparation Keep the device far from radio transmitting stations, radar stations, and high-frequency devices. Use electromagnetic shielding when necessary, for example, use shielded interface cables. Route interface cables only indoors to prevent signal ports from getting damaged by overvoltage or overcurrent caused by lightning strikes.
  • Page 27: Chapter 3 Installing The Switch

    When the depth of a switch is greater than 300 mm (11.8 in), the front mounting ears only secure the switch rather than bear its weight. Guide rails purchased from H3C apply only to standard cabinets 1,000 mm (39.4 in) deep. Use other supports to substitute for guide rails in the case of other cabinet depths.
  • Page 28 Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch (1) Screw hole used to fix the mounting ear to the cabinet (Use one M6 screw) (2) Screw hole used to fix the switch to the mounting ear Figure 3-1 Appearance of a standard front mounting ear Figure 3-2 shows the appearance of a rear mounting ear.
  • Page 29 Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch Slotted hole 1 Cooling hole Slotted hole 2 Slotted hole 1: Used to fix the guide rail to the rear bracket. You can adjust the screw hole position according to the position of the switch.
  • Page 30 Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch Place the switch on the tray horizontally, slide the tray into the cabinet, and fix the other end of mounting ears to the front brackets with crews and captive nuts, as shown in Figure 3-5.
  • Page 31 Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch Three installation locations for screw 1 (select one according to the actual requirement) Three installation locations for screw 1 (select one according to the actual requirement) Screw 1...
  • Page 32 Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch Hold the bottom of the switch with one hand and the front part of the switch with the other hand, and push the switch into the cabinet gently, as shown in Figure 3-8.
  • Page 33 Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch Fix the other end of the front mounting ears to the front brackets with screws and captive nuts and ensure that front and rear mounting ears have fixed the switch in the cabinet securely, as shown in Figure 3-10.
  • Page 34 Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch Figure 3-11 Install guide rails Hold the two sides of the switch and slide it gently along the guide rails into the cabinet until it is located in a proper position, as shown in Figure 3-12. Ensure that the bottom side of the guide rails and the switch are in close contact.
  • Page 35: Desk Mounting

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch Guide Rear panel rail Figure 3-13 Effect diagram of front mounting ear and guide rail installation Note: Ensure a clearance of 1U (44.45 mm, namely, 1.75 inches) between devices for the purpose of heat dissipation.
  • Page 36: Installing Power Module

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch 3.2 Installing Power Module Caution: Do not touch any leads, terminals and parts marked with the hazard voltage label to avoid body harm. 3.2.1 Installing a Power Module Step 1: Draw on the ESD-preventive wrist strap and ensure that the strap is well grounded.
  • Page 37: Connecting The Power Cord And The Ground Wire

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch Caution: The S5510 series supports the online-swap of power module. That is, you can install/remove a power module while keeping another power module operating in the switch. Before you install/remove a power module, you must first power down the module.
  • Page 38: Connecting The Dc-Input Power Cord

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch Step 3: Verify that the PWR LED on the front panel of the switch is ON. Caution: Before powering on the switch, connect the ground wire. 3.3.2 Connecting the DC-Input Power Cord +...
  • Page 39: Connecting The Ground Wire

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch Caution: Before powering on the switch, connect the ground wire. The length of the DC power cord must be less than 3 m (9.8 ft.). 3.3.3 Connecting the Ground Wire...
  • Page 40 Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch When there is no grounding strip but earth near the equipment room that allows a grounding body to be buried, hammer an angle iron/steel pipe longer than 0.5 m into the earth, weld the yellow-green ground wire of the switch onto the angle iron/steel pipe, and process the joint against erosion.
  • Page 41: Multi-Power Input

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch (11) (11) (10) (10) (1) AC/DC power cabinet (2) -48V strip (3) -48V (4) RTN strip (5) RTN (6) PGND strip (7) Grounding (8) Ground wire (9) Grounding screw...
  • Page 42: Connecting The Switch To A Console Terminal

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch 3.5 Connecting the Switch to a Console Terminal 3.5.1 Console Cable Console cable is an 8-core cable. At one end of the cable is a crimped RJ-45 connector for the connection to the Console port of the switch;...
  • Page 43: Verifying Installation

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 3 Installing the Switch Caution: Read the mark for the port to be connected carefully to make sure it is the right port. Note: The serial ports on PCs do not support hot swapping. Therefore, do not insert or remove a serial interface cable from a PC that is connected to a switch with power.
  • Page 44: Chapter 4 Starting Up The Switch At The Initial Boot

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot Chapter 4 Starting up the Switch at the Initial Boot 4.1 Setting up a Configuration Environment Set up a configuration environment as shown in Figure 4-1.
  • Page 45 Installation Manual H3C S5510 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot The HyperTerminal window displays the Connection Description dialog box, as shown in Figure 4-2. Figure 4-2 Setting up a new connection Step 2: Enter the name of the new connection in the Name field and click <OK>. The dialog box, as shown in Figure 4-3 displays.
  • Page 46 Installation Manual H3C S5510 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot Parity check = none Stop bits = 1 Flow control = none Figure 4-4 Setting communications parameters Step 6: Click <OK>. The HyperTerminal dialogue box appears.
  • Page 47: Booting The Switch

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot Step 9: Select VT100 or Auto detect in the Emulation dropdown menu. Step 10: Click <OK>. Figure 4-6 Settings tab 4.4 Booting the Switch 4.4.1 Verifying Installation before Power-up...
  • Page 48 Installation Manual H3C S5510 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot H3C S5510-24P BOOTROM, Version 107 ********************************************* Copyright(c) 2004-2006 Hangzhou H3C Technologies Co., Ltd. Creation date : Apr 28 2006, 11:27:16 CPU type : MPC8241...
  • Page 49 You can configure the switch now. Note: A wide range of command views are available for H3C Series Switches. For more information on configuration commands and command line interfaces, refer to H3C S3610&S5510 Series Ethernet Switches Operation Manual and H3C S3610&S5510...
  • Page 50: Chapter 5 Loading Boot Rom And Host Software

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Chapter 5 Loading Boot ROM and Host Software Switch software loading through serial ports in the past is time consuming and cannot be operated remotely. To address these problems, TFTP and FTP are used to allow software and file downloading through Ethernet ports.
  • Page 51 Installation Manual H3C S5510 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software H3C S5510-24P BOOTROM, Version 129 ********************************************* Copyright(c) 2004-2007 Hangzhou H3C Technologies Co., Ltd. Creation date : Apr 16 2007, 11:27:16 CPU type : MPC8241 CPU Clock Speed : 200MHz...
  • Page 52: Loading Software From Console Port Using Xmodem

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software 9. Set switch startup mode 0. Reboot Enter your choice(0-9): 5.2.2 Loading Software from Console Port Using XModem I. Introduction to XModem XModem is a file transfer protocol widely used for its simplicity and good performance.
  • Page 53 Installation Manual H3C S5510 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Enter your choice (0-5): Step 3: Choose an appropriate download baud rate. Enter <5> for example to download at 115200 bps. The system displays the following information:...
  • Page 54 Installation Manual H3C S5510 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Figure 5-2 Console Port Configuration dialog box Step 5: Click <Disconnect> to disconnect the HyperTerminal from the switch and then click <Call> to re-establish the connection, thus validating the baud rate setting.
  • Page 55 Installation Manual H3C S5510 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Step 6: Press <Enter> to start program loading. The system displays the following information: Now please start transfer file with XMODEM protocol. If you want to exit, Press <Ctrl+X>.
  • Page 56: Loading Software From An Ethernet Port Using Tftp

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Note: You do not need to reset the HyperTerminal’s baud rate and can skip the last step if you have chosen 9600 bps. In this case, the system does not display the above prompt message but “BootROM is updating now........done”...
  • Page 57 Caution: TFTP Server program is not provided with the H3C Series Switches. Step 3: Run terminal emulation program on the PC that is connected to the Console port. Start the switch, access the Boot Menu, and then enter the download protocol menu.
  • Page 58: Loading Software From An Ethernet Port Using Ftp

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Checking flash..done! III. Loading host software Follow these steps to download host software of the switch. Step 1: Select <1> in the Boot Menu. The system displays the following information: 1.
  • Page 59: Loading Software Remotely

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software 3. Set XMODEM protocol parameter 0. Return to boot menu Enter your choice(0-3): Step 4: In the download protocol menu, press <2> to select FTP protocol to download Boot ROM and host software.
  • Page 60: Loading Software Remotely Using Ftp

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software 5.3.1 Loading Software Remotely Using FTP Run FTP server on a local PC, provided you have configured username and password and have set the correct file directory. Suppose IP address of the PC is 10.10.110.1.
  • Page 61: Loading Software Remotely Using Tftp

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software To validate the downloaded Boot ROM and host software, you must reboot the switch. In case of inadequate Flash memory space, you can delete some of the program files in Flash, those that are no longer in use for example, after completing Boot ROM loading.
  • Page 62: Chapter 6 Maintenance And Troubleshooting

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 6 Maintenance and Troubleshooting Chapter 6 Maintenance and Troubleshooting 6.1 Dealing with Loading Failures If software loading fails, the system operates with the original version. To address the failure cause, take these steps: Verify that the physical ports are correctly and securely connected.
  • Page 63: Recovering The Boot Rom Password

    Installation Manual H3C S5510 Series Ethernet Switches Chapter 6 Maintenance and Troubleshooting Select <7> and have the switch reboot. The user password is deleted at the reboot to allow you access the switch without password. 6.2.2 Recovering the Boot ROM Password Contact your sales agent for help.
  • Page 64 Installation Manual H3C S5510 Series Ethernet Switches Table of Contents Table of Contents Appendix A Lightning Protection of the Switch.................A-1 A.1 Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection)....A-1 A.2 Installation of Lightning Arrester for Network Port.............A-2...
  • Page 65: Appendix A Lightning Protection Of The Switch

    Installation Manual H3C S5510 Series Ethernet Switches Appendix A Lightning Protection of the Switch Appendix A Lightning Protection of the Switch A.1 Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection) Caution: Lightning arrester will not be shipped with the switch. You should purchase it by yourself if needed.
  • Page 66 Installation Manual H3C S5510 Series Ethernet Switches Appendix A Lightning Protection of the Switch Caution: Make sure that the arrester is well grounded before using the lightning arrester for power. After inserting AC power cord plug of switch into the socket of lightning arrester, if the green LED is on and the red LED does not alarm, it means that the lightning arrester of power is running and the function of lightning protection has taken effect.
  • Page 67 Installation Manual H3C S5510 Series Ethernet Switches Appendix A Lightning Protection of the Switch I. Required tools Phillips screwdriver or Flat-blade screwdriver Multimeter Tilted wire cutter II. Installation procedure Step 1: Tear the protection paper at one side of the double faced adhesive tape apart from the tape, and stick the tape on the surface of the arrester.
  • Page 68 Installation Manual H3C S5510 Series Ethernet Switches Appendix A Lightning Protection of the Switch Network cable indoors Network cable led into from outdoor Lightning arrester for network port (attached onto the chassis) Switch Ground wire of lightning arrester Power input...