transceiver monitor interval

Use
transceiver monitor interval
Use
undo transceiver monitor interval
Syntax
transceiver monitor interval interval
undo transceiver monitor interval
Default
The transceiver monitoring interval is 600 seconds.
Views
System view
Predefined user roles
network-admin
Parameters
: Specifies the transceiver monitoring interval in seconds. The value range is 300 to
interval
3600.
Usage guidelines
After transceiver monitoring is enabled, the device samples the parameters of transceiver modules
periodically, including the input power and output power of transceiver modules. If a sampled value
reaches the alarm threshold, the device generates a log entry to notify users.
This command takes effect only when the
executed.
Examples
# Set the transceiver monitoring interval to 500 seconds.
<Sysname> system-view
[Sysname] transceiver monitor interval 500
Related commands
transceiver monitor enable

temperature-limit

Use
temperature-limit
Use
undo temperature-limit
Syntax
temperature-limit
warninglimit [ alarmlimit ]
undo temperature-limit slot slot-number hotspot sensor-number
Default
The defaults vary by temperature sensor model. To view the defaults, execute the
temperature-limit
to set a transceiver monitoring interval.
transceiver monitor enable
to set the temperature alarm thresholds.
to restore the default.
slot
slot-number
and
display environment
55
to restore the default.
hotspot
sensor-number
commands in turn.
command is
lowlimit
undo