shutdown-interval

Use
shutdown-interval
Use
undo shutdown-interval
Syntax
shutdown-interval interval
undo shutdown-interval
Default
The port status detection timer setting is 30 seconds.
Views
System view
Predefined user roles
network-admin
Parameters
: Specifies the port status detection timer value in seconds,the value range is 0 to 3600.
interval
To disable port status detection, set this argument to 0.
Usage guidelines
The device starts a port status detection timer when a port is shut down by a protocol. Once the timer
expires, the device brings up the port so the port status reflects the port's physical status.
If you change the timer setting during port detection, the device compares the new setting (T1) with
the time that elapsed since the port was shut down (T).
If T < T1, the port will be brought up after T1 – T seconds.
If T ≥ T1, the port is brought up immediately.
For example, the timer setting is 30 seconds. If you change it to 10 seconds 2 seconds after the port
is shut down, the port will come up 8 seconds later. If you change the timer setting to 2 seconds 10
seconds after the port is shut down, the port comes up immediately.
Examples
# Set the port status detection timer to 100 seconds.
<Sysname> system-view
[Sysname] shutdown-interval 100

sysname

Use
sysname
Use
undo sysname
Syntax
sysname sysname
undo sysname
Default
The device name is H3C.
to set the port status detection timer.