clock protocol

Use
clock protocol
Use
undo clock protocol
Syntax
clock protocol { none | ntp }
undo clock protocol
Default
The device obtains the UTC time from an NTP time source.
Views
System view
Predefined user roles
network-admin
Parameters
: Uses the system time set by using the
none
: Uses NTP to obtain the UTC time. You must configure NTP correctly. For more information
ntp
about NTP and NTP configuration, see Network Management and Monitoring Configuration Guide.
Usage guidelines
Correct system time is essential to network management and communication. You must configure
the system time correctly before you run the device on the network.
The device can use the locally set system time, or obtain the UTC time from a time source on the
network and calculate the system time.
If you execute the
The device then uses the clock signals generated by its built-in crystal oscillator to maintain the
system time.
If you execute the
and calculates the system time. The device then periodically synchronizes the UTC time and
recalculates the system time.
If you execute this command multiple times, the most recent configuration takes effect.
Examples
# Configure the device to use the local UTC time.
<Sysname> system-view
[Sysname] clock protocol none

clock summer-time

Use
clock summer-time
Use
undo clock summer-time
Syntax
clock summer-time name start-time start-date end-time end-date add-time
undo clock summer-time
to specify the system time source.
to restore the default.
clock protocol none
clock protocol ntp
to set the daylight saving time.
to restore the default.
clock datetime
command, the device uses the locally set system time.
command, the device obtains the UTC time through NTP
6
command.