Temperature shutdown LED
Management Ethernet port
Console port
ESD point
Power supply or power supplies
Figure 4 on page 31
shows the rear panel of an EX4200 switch with power supplies and fan tray installed.
The rear panel of all the EX4200 switches except EX4200-24F-S and EX4200-48T-S switches are similar.
All EX4200 switches except the EX4200-24F-S and EX4200-48T-S switches are shipped with the power
supplies and fan tray pre-installed in the rear panel of the switch. The power supplies and the fan tray for
the EX4200-24F-S and EX4200-48T-S models are not shipped by default; you must order them separately
and install them in the rear panel. The 320 W AC power supply and the 190 W DC are flush with the
chassis. The 600 W AC power supply and 930 W AC power supply extend out of the chassis by 2.25 in.
Power cord retainer clips extend out of the power supply by 3 in.
Figure 4: EX4200 Switch Rear Panel
Temperature
shutdown LED
Fan
Virtual
USB
Management
tray
chassis
port
Ethernet
ports
port

LCD Panel in EX4200 Switches

IN THIS SECTION
LCD Panel Modes | 32
The LCD panel on the front panel of the switch shows two lines of text, each of which can contain a
maximum of 16 characters. The LCD panel displays a variety of information about the switch and also
provides a menu to perform basic operations such as initial setup and reboot.