2.0

Installation and Wiring

This section is provided to help the installer and describes the procedures for installing the IQ plus 810 XPCD
indicator and enclosure, AC wiring, load cell wiring, conduit runs and internal modifications for the IQ plus 810
XPCD.
2.1

IQ plus 810 XPCD Enclosure

The following sections describe mounting locations and how to mount the enclosure, sealoff the fittings, and how
to properly gasket the enclosure.
2.1.1

Mounting and Mounting Locations

The mounting and installation of an explosion proof enclosure is more involved than a general purpose unit and it
is recommended that all outdoor installations have a shelter, roof, enclosure, or covering. The IQ plus 810 XPCD
enclosure is cast aluminum and direct sunlight can cause it to heat to a very high temperature which can damage
the electronics inside. (Such damage is not covered by the warranty). Sheltering the unit from sunlight will help
control the internal temperature. In cold climates, it is recommended an indicator heater be installed (optional).
These are small and easily installed on the backplate.
Sunlight and variable temperatures can also cause moisture to condensate inside the enclosure. It is
recommended to shelter the outdoor installation by a shelter, roof, enclosure, or covering. Moist environments
can also be controlled by the use of desiccants. Contact your local dealer for information on desiccants.
Do not place desiccants on top of circuit boards. Place them in the bottom of the
Caution
!
enclosure away from electronics and wires.
The explosion proof enclosure is substantially heavier than a standard enclosure and thus the mounting surface
must be capable of reliably supporting the added weight.
The mounting and installation of the IQ plus 810 XPCD must be into Division II or safe electrical area per NEC,
Section 500. The inside of an explosion proof enclosure is classified as a Division II environment.
Switches and Glass
The glass and switches on the IQ plus 810 XPCD may look indestructible but they are not. If damaged in any
way, the entire unit must be completely turned off at the source until it is replaced. The enclosure must be
protected from blows and scrapes from passing equipment, falling objects, thick glues or resins, certain acids
which eat aluminum, and other hazards which can break or damage the enclosure.
The glass window in the enclosure must be not become scratched, pitted, or damaged in any way. Do not wipe
the glass with dirty gloves or rags as this can cause the glass to become scratched.
Bolts
The manufacturer has provided the proper bolts to ensure that the door to this unit remains sealed. One or two
bolts is not enough. Use all of the enclosed bolts to maintain a tight seal. Therefore, all bolts must be installed
and kept tightly fastened at all times.