Endress+Hauser Mycom CLM 152 Operating Instructions Manual page 100

Conductivity measuring transmitter
Hide thumbs Also See for Mycom CLM 152:
Table of Contents

Advertisement

Menu structure
Instrument data
PARAM
Short operation
Start-up
98
Parameter
System
configuration
Code
Output contacts
General settings
General settings
Current output
Current output 1
Current output 2
Temperature
Temperature
compensation
Temperature
measurement
Meas. range 1-4
Select substance
(only for FBU)
Hold for calibration
Calibration
no
yes
Limit contactor
Limit configuration
Alarm configuration
Operating mode
No. of MRs
Internal MRS
no switch point 1
2 switch points 2
4 switch points 3
Chemoclean
Hysteresis
USP
On delay
Hold on
Hold
Hold off
Limit contactor 1
Limit operating
Limit contactor 2
mode
Meas. range 1-4
Setpoints
Automatic in
Chemoclean
Automatic off
Start cleaning
Language
Dispaly contrast
Deutsch, English,
Francais, Italiano
Measuring type
Measuring cell
Conductivity
CLS 50, CLS 52,
Resistance
2-ring: k = 0,01;
k = 0,1; k = 1; k = 10
Repair code
Specialist code
Rerlay function
NAMUR contact type
(dep. on configuration)
NC contact
NO contact
Language
Filter length
Deutsch, English,
Francais, Italiano
Current monitoring
Error current
(cable break monitoring)
off
active
MIN current
inactive
MAX current
Meas. current range
Output damping
Current output 1
Current output 1
0 ... 20 mA
4 ... 20 mA
2nd current output
Meas. current range
Current output 2
(only for difference)
0 ... 20 mA
4 ... 20 mA
Select meas. range
Type of Tc
no comp.
(only with FBU)
linear
NaCl DIN 746
Tc curve
Ultrapure water NaCL
Ultrapure water User
Temperature
(MTC)
manual
(MTC)
Temperature 1
automatic (ATC)
(ATC)
set offset
Temperature
actual value 1
Select substance
Substance name
(for non-preprog.
substance)
ATC cal. solution
Calibration temperature
(for MTC)
Limit contactor 1
Off
Limit contactor 2
On
Select alarm
Meas. range
dependent
Meas. range
independent
Limit contactor 1
Operating mode
Limit contactor 2
Auto
Manual
MR value threshold 1
MR value threshold 2
(not for 1)
(not for 1)
Hysteresis
Operating mode
Limit contact
Auto
off/on
Manual
Limit 1
Meas. range 1-4
Date
Time
Mycom CLM 152
Measurinv principle
Unit
1-circuit
Difference
(only difference)
Contact type failure
Allign faults
relay
to maintenance
Fleeting contact
contact
Steady contact
to no contact
Temperature unit
Date
°C, °F , K
Hold type
Hold current
fixed current value
lat measured value
(only for fixed
current value)
Select characteristic
linear
linear, bilinear,
log. table
Output damping
Select characteristic
Current output 2
linear
linear, bilinear,
log. table
Ref. temperature
for linear
for Tc curve
Select substance
(MTC)
Temperature 2
(only for difference)
(ATC)
(ATC)
Set offset
Display temperature
Temperature
offset
actual value 2
No. of support points
Susbtance table
Substance
Meas. range
dependent
Meas. range
Meas. range 1-4
independent
Meas. range 1-4
Alarm threshold
Alarm delay
Limit contact
off/on
MR value threshold 3
MR value threshold 4
(not for 1+2)
(not for 1+2)
Limit 2
Measuring type
Measuring principle
Conductivity
Resistance (M )
(only for difference)
Temperature sensor 1
PT 100
PT 1000
NTC 30 kW
Time
Temperature coeff.
Tc
Substance name
Support points
Tc curve
Meas. range 1-4
Min/Max
function
Setting
Automatic on
Automatic off
SI unit
mS/cm, mS/cm
mS/m, S/m
Endress+Hauser