Endress+Hauser Mycom CLM 152 Operating Instructions Manual page 96

Conductivity measuring transmitter
Hide thumbs Also See for Mycom CLM 152:
Table of Contents

Advertisement

Menu structure
Instrument data
PARAM
Short operation
Start-up
94
Parameter
System
configuration
Code
Output contacts
General settings
General settings
Current output
Current output 1
Current output 2
Temperature
Temperature
compensation
Temperature
measurement
Select substance
Meas. range 1-4
(only for FBU)
Hold on calibration
Calibration
no
yes
Limit contactor
Limit configuration
Alarm configuration
Operating mode
No. of MRs
Internal MRS
no switch point 1
2 switch points 2
4 switch points 3
Chemoclean
Hold on
Hold
Hold off
Limit contactor 1
Limit operation
Limit contactor 2
mode
Meas. range 1-4
Setpoints
Chemoclean
Automatic on
Automatic off
Start cleaning
Language
Display contrast
Deutsch, English,
Francais, Italiano
Air set
bypass
perform
Measuring cell
Meas. type
Measuring cell
Conductivity
CLS 50, CLS 52,
Concentration
2-ring: k = 0,01;
Resistance
k = 0,1; k = 1; k = 10
Mainteance code
Specialist code
Relay function
NAMUR contact type
(dep. on configuration)
NC contact
NO contact
Language
Filter length
Deutsch, English,
Francais, Italiano
Current monitoring
Error current
off
(cable break monitoring)
active
MIN current
inactive
MAX current
Meas. current range
Output damping
Current output 1
Current output 1
0 ... 20 mA
4 ... 20 mA
2nd current output
Meas. current range
Current output 2
(only for difference)
0 ... 20 mA
4 ... 20 mA
Select meas. range
Type of Tc
no comp.
(only on FBU)
linear
NaCl DIN 746
Tc curve
Temperature
(MTC)
manual
(MTC)
Temperature 1
automatic
(ATC)
(ATC)
Set offset
Temperature 1
actual value
Select substance
Substance name
(for non-preprog.
substance)
ATC cal. sol.
Calibration temperature
(at MTC)
Limit contactor 1
Off
Limit contactor 2
On
Select alarm
Meas. range
dependent
Meas. range
independent
Limit contactor 1
Operating mode
Limit contactor 2
Auto
Manual
MR value threshold 1
MR value threshold 2
(not for 1)
(not for 1)
Operating mode
Limit contact
Auto
off/on
Manual
Limit 1
Meas. range 1-4
Date
Time
Instruction
Calibrating
Mycom CLM 152
Meas. principle
Unit
1-circuit
Difference
(only difference)
Contact type failure
Assign faults
relay
to maintenance
Fleeting contact
contact
Steady contact
to no contact
Temperature unit
Date
°C, °F , K
Hold type
Hold current
fixed current value
last measured value
(only for fixed
current value)
Select characteristic
linear
linear, bilinear,
log. table
Output damping
Select characteristic
Current output 2
linear
linear, bilinear,
log. table
Ref. temperature
for linear
with Tc curve
Select substance
(MTC)
Temperature 2
(only for difference)
(ATC)
(ATC)
Set offset
Display temperature
Temperature 2
offset
actual value
No. of support points
Substance table
Substance
Meas. range
dependent
Meas. range
Meas. range 1-4
independent
Meas. range 1-4
Alarm threshold
Alarm delay
Limit contact
off/on
MR value threshold 3
MR value threshold 4
(not for 1+2)
(not for 1+2)
Limit 2
Meas. type
Meas. principle
Conductivity
Concentration
(only for difference)
Input contact
(only with FCXI card)
Note
Temperature sensor 1
PT 100
PT 1000
NTC 30 kW
Time
Temperature coeff.
Tc
Susbtance name
Support points
Tc curve
Meas. range 1-4
Min/Max
function
Setting
Automatic on
Automatic off
SI unit
mS/cm, mS/cm
mS/m, S/m
Relay function
(dep. on configuration)