PC.01
Baud rate
selection
This parameter can set the data transmission rate during serial communication.
Notice: The baud rate of master and slave must be the same.
Function
Name
Code
Data
PC.02
format
This parameter defines the data format used in serial communication protocol.
0: RTU, 1 start bit, 8 data bits, no parity Communication 1 stop bit.
1: RTU, 1 start bit, 8 data bits, even parity Communication, 1 stop bit.
2: RTU, 1 start bit, 8 data bits, odd parity Communicationk, 1 stop bit.
3: RTU, 1 start bit, 8 data bits, no parity Communication 2 stop bits.
4: RTU, 1 start bit, 8 data bits, even parity Communication, 2 stop bits.
5: RTU, 1 start bit, 8 data bits, odd parity Communication, 2 stop bits.
6: ASCII, 1 start bit, 7 data bits, no parity Communication, 1 stop bit.
7: ASCII, 1 start bit, 7 data bits, even parityCommunication, 1 stop bit.
8: ASCII, 1 start bit, 7 data bits, odd parity Communication, 1 stop bit.
9: ASCII, 1 start bit, 7 data bits, no parity Communication 2 stop bits.
10: ASCII, 1 start bit, 7 data bits, even parity Communication, 2 stop bits.
11: ASCII, 1 start bit, 7 data bits, odd parity Communication, 2 stop bits.
12: ASCII, 1 start bit, 8 data bits, no parity Communication, 1 stop bit.
13: ASCII, 1 start bit, 8 data bits, even parityCommunication, 1 stop bit.
14: ASCII, 1 start bit, 8 data bits, odd parity Communication 1 stop bit.
15: ASCII, 1 start bit, 8 data bits, no parity Communication, 2 stop bits.
16: ASCII, 1 start bit, 8 data bits, even parity Communication, 2 stop bits.
17: ASCII, 1 start bit, 8 data bits, odd parity Communication, 2 stop bits.
Function
Code
0: 1200BPS
1: 2400BPS
2: 4800BPS
3: 9600BPS
4: 19200BPS
5: 38400BPS
Description
Name
Description
0~5
0~17
Setting
77
3
Setting
Factory
Range
Setting
0~17
0
Factory
range
Setting