DC braking will take effect only when P1.00 is set to be 1.
DC braking is invalid when P1.04 is set to be 0.
The value of P1.03 is the percentage of rated current of inverter. The bigger the DC
braking current, the greater the braking torque.
Function
Code
P1.05
Stop mode
0: Deceleration to stop
When the stop command takes effect, the inverter decreases the output frequency according
to the selected acceleration/deceleration time till stop.
1: Coast to stop
When the stop command takes effect, the inverter blocks the output immediately. The motor
coasts to stop by its mechanical inertia.
Function
Code
Starting frequency of DC
P1.06
Waiting time before DC
P1.07
P1.08
DC braking current
P1.09
Starting frequency of DC braking: Start the DC braking when output frequency reaI5000s
starting frequency determined by P1.06.
Waiting time before DC braking: Inverter blocks the output before starting the DC braking.
After this waiting time, the DC braking will be started. It is used to prevent over-current fault
caused by DC braking at high speed.
DC braking current: The value of P1.08 is the percentage of rated current of inverter. The
bigger the DC braking current, the greater the braking torque.
DC braking time: The time used to perform DC braking. If the time is 0, the DC braking will be
invalid.
Name
0: Deceleration to stop
1: Coast to stop
Name
braking
braking
DC braking time
Description
Description
0.00~P0.04
0.0~50.0s
0.0~150.0%
0.0~50.0s
42
Setting
Factory
Range
Setting
0~1
Setting
Factory
Range
Setting
0.00~50.00
0.00Hz
0.0~50.0
0.0s
0.0~150.0
0.0%
0.0~50.0
0.0s
0