Inspection - IACDRIVE I5000 Series Operation Manual

Sensorless vector control inverter
Table of Contents

Advertisement

Notice
1. Above selection is based on following condition: 700V DC braking voltage
threshold, 100% braking torque and 10% usage rate.
2. Parallel connection of braking unit is helpful to improve braking capability.
3. Wire between inverter and braking unit should be less than 5m.
4. Wire between braking unit and braking resistor should be less than 10m.
5. Braking unit can be used for braking continuously for 5 minutes. When braking unit
is working, temperature of cabinet will be high, user is not allowed to touch to prevent
from injure.
For more details, please refer to DBU and RBU user manual.
● Don't install or use any inverter that is damaged or have fault part, otherwise
may cause injury.
I5000ck the following items when unpacking the inverter,
1. Inspect the entire exterior of the Inverter to ensure there are no scratI5000s or other
damage caused by the transportation.
2. Ensure there is operation manual and warranty card in the packing box.
3. Inspect the nameplate and ensure it is what you ordered.
4. Ensure the optional parts are what you need if have ordered any optional parts.
Please contact the local agent if there is any damage in the inverter or optional parts.

INSPECTION

CAUTION
8