Advertisement

Figure 6.25 Relationship between bias limit and output frequency.
Function
Code
P9.09
P9.10
When feedback value is less than P9.09 continuously for the period determined by P9.10,
the inverter will alarm feedback lost failure (PIDE).
Notice: 100% of P9.09 is the same as 100% of P9.01.
6.11 PA Group-- Multi-step Speed Control
Function
Code
PA.00
Multi-step speed 0
PA.01
Multi-step speed 1
PA.02
Multi-step speed 2
PA.03
Multi-step speed 3
PA.04
Multi-step speed 4
PA.05
Multi-step speed 5
Name
Feedback lost
detecting value
Feedback lost
detecting time
Name
-100.0~100.0%
-100.0~100.0%
Description
0.0~100.0%
0.0~3600.0s
Description
-100.0~100.0%
-100.0~100.0%
-100.0~100.0%
-100.0~100.0%
71
Setting
Factory
Range
Setting
0.0~100.0
0.0~3600.0
Setting Range
-100.0~100.0
-100.0~100.0
-100.0~100.0
-100.0~100.0
-100.0~100.0
-100.0~100.0
0.0%
1.0s
Factory
Setting
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%