initialization is completed, the inverter is on stand-by status.
5.3.2 Stand-by
At stop or running status, parameters of multi-status can be displayed. Whether or not to display
this parameter can be chosen through Function Code P7.06(Running status display selection )
and P7.07 (Stop status display selection) according to binary bits, the detailed description of each
bit please refer the function code description of P7.06 and P7.07.
In stop status, there are nine parameters which can be chosen to display or not. They are:
reference frequency, DC bus voltage, ON-OFF input status, open collector output status, PID
setting, PID feedback, analog input FV voltage, analog input FI voltage, step number of multi-step
speed. Whether or not to display can be decided by setting the corresponding binary bit of P7.07.
Press the
SHIFT to scroll through the parameters in right order. Press DATA/ENT +
QUICK/JOG to scroll through the parameters in left order.
5.3.3 Motor parameter auto tuning
For details, please refer to the description of P0.12.
5.3.4 Operation
In running status, there are fourteen running parameters: output frequency, reference frequency,
DC bus voltage, output voltage, output current, output power, output torque, PID setting, PID
feedback, ON-OFF input status, open collector output status, length value, count value, step
number of PLC and multi-step speed, voltage of FV, voltage of FI and step number of multi-step
speed. Whether or not to display can be decided by the
bit option of Function Code P7.06 (converted into binary system). Press the
SHIFT to scroll
through the parameters in right order . Press DATA/ENT + QUICK/JOG to scroll through the
parameters in left order.
5.3.5 Fault
I5000 series inverter offers a variety of fault information. For details, see inverter faults and their
troubleshooting.