IACDRIVE I5000 Series Operation Manual page 51

Sensorless vector control inverter
Table of Contents

Advertisement

P5.00
P5.01
P5.02
P5.03
P5.04
P5.05
The meaning of each setting is shown as follows.
0: Invalid
1: Forward
2: Reverse
3: 3-wire control
Please refer to description of P5.05.
4: Jog forward
5: Jog reverse
Please refer to description of P8.02~P8.04.
6: Coast to stop
The inverter blocks the output immediately. The motor coasts to stop by its mechanical inertia.
7: Reset fault
It is used for fault reset in distance. It has the same function as STOP/RST.
8: External fault input
Stop the inverter and output a alarm when a fault occurs in a peripheral device.
9: UP command
10:DOWN command
11:Clear UP/ DOWN
The reference frequency can be adjusted by UP command and DOWN command, and Clear
UP/DOWN is used to back to the reference frequency.
12,13,14: Multi-step speed terminal1~3
8-step speed control can be realized by the combination of these 3 terminals
15: ACC/DEC time selection
Terminal
OFF
ON
16: PID pause
PID adjustment will be paused and inverter keeps output frequency unchanged.
17: Pause traverse
Inverter keeps output frequency unchanged. If this terminal is disabled, inverter will continue
traverse operation from current frequency.
18: Reset traverse operation
Reference frequency of inverter will be forced as center frequency of traverse operation.
19: ACC/DEC ramp hold
Ensure inverter will not be affected by outside signals and keep the current output frequency
S1 Terminal function selection
S2 Terminal function selection
S3 Terminal function selection
S4 Terminal function selection
S5 Terminal function selection
S6 Terminal function selection
ACC/DEC time selection
Acceleration Time 0
Acceleration Time 1
Corresponding parameter
P0.11, P0.12
P8.00, P8.01
49
0~55 [1]
0~55 [4]
0~55 [7]
0~55 [0]
0~55 [9]
0~55 [10]