IACDRIVE I5000 Series Operation Manual page 68

Sensorless vector control inverter
Table of Contents

Advertisement

Function
Code
Frequency arrive
P8.15
detecting range
When output frequency is within the detecting range of reference frequency, an ON-OFF
signal will be output.
Function
Name
Code
Brake threshold
P8.16
voltage
When the DC bus voltage is greater than the value of P8.16, the inverter will start
dynamic braking.
Notice:
Factory setting is 120% if rated voltage of inverter is 220V.
Factory setting is 130% if rated voltage of inverter is 380V.
The value of P8.16 is corresponding to the DC bus voltage at rated input voltage.
Name
Figure 6.19 Frequency arriving signal diagram.
Description
0.0~100.0%
(maximum
frequency)
Description
115.0~140.0%
66
Setting
Factory
Range
Setting
0.0~100.0
0.0%
Factory
Setting Range
Setting
Depend
115.0~140.0
on model