Rise time of
P8.09
P8.10
Traverse operation is widely used in textile and I5000mical fiber industry. The typical application
is shown in following figure.
Traverse amplitude (AW) =center frequency (CF) * P8.08% Jitter
frequency = traverse amplitude (AW) * P8.08%
Rise time of traverse: Indicates the time rising from the lowest traverse frequency to the highest
traverse frequency.
Fall time of traverse: Indicates the time falling from the highest traverse frequency to the lowest
traverse frequency.
Notice:
P8.07 determines the output frequency range which is as below:
(1-P8.07%) * reference frequency ≤ output frequency ≤ (1+P8.07%) * reference frequency
The output frequency of traverse is limited by upper frequency limit (P0.05) and lower
frequency limit (P0.06).
Function
Code
P8.11
P8.12
traverse
Fall time of
traverse
Figure 6.17 Traverse operation diagram.
Center frequency (CF) is reference frequency.
Name
Auto reset times
Reset interval
0.1~3600.0s
0.1~3600.0s
Description
0~3
0.1~100.0s
64
0.1~3600.0
5.0s
0.1~3600.0
5.0s
Setting
Factory
Range
Setting
0~3
0.1~100.0
1.0s
0