Function
Name
Code
Frequency A
P0.03
command
source
0: Keypad: Please refer to description of P3.00
1: FV
2: FI
3:FV+FI
The reference frequency is set by analog input. I5000 series inverter provides 2 analog input
terminals. FV is 0~10V voltage input terminal, while FI is 0~10V voltage input or 0~20mA
current input. Voltage input or current input of FI can be selected by Jumper J16.
Notice:
When FI is set as 0~20mA current input, the corresponding voltage range is
0~5V.
4: Multi-step speed
The reference frequency is determined by PA group. The selection of steps is determined by
combination of multi-step speed terminals.
Notice:
Multi-step speed mode will enjoy priority in setting reference frequency if P0.03 is
not set to be 4. In this case, only step 1 to step 15 are available.
If P0.03 is set to be 4, step 0 to step 15 can be realized.
Jog has highest priority.
5: PID
The reference frequency is the result of PID adjustment. For details, please refer to description
of P9 group
6: Communication
The reference frequency is set through RS485. For details, please refer to description of
Chapter 10.
Description
0: Keypad
1: FV
2. FI
3: FV+FI
4. Multi-Step speed
5: PID
6: Communication
35
Setting
Factory
Range
Setting
0~6
0