Function
Name
Code
Running status
P7.06
display selection
Stop status display
P7.07
selection
Rectifier module
P7.08
temperature
IGBT module
P7.09
temperature
Description
0~0X7FFF
BIT0: Output frequency
BIT1: Reference frequency
BIT2: DC bus voltage
BIT3: Output voltage
BIT4: Output current
BIT5: Rotation speed
BIT6: Output power
BIT7: Output torque
BIT8: PID preset
BIT9: PID feedback
BIT10: Input terminal status
BIT11: Output terminal status
BIT12: FV
BIT13: FI
BIT14: Step No. of multi-step
BIT15: Reserved
0~0X1FF
BIT0: Reference frequency
BIT1: DC bus voltage
BIT2: Input terminal status
BIT3: Output terminal status
BIT4: PID preset
BIT5: PID feedback
BIT6: FV
BIT7: FI
BIT8: Step No. of multi-step
BIT9~15: Reserved
0~100.0℃
0~100.0℃
100
Factory
Serial
Modify
Setting
No.
0XFF
O
84
0xFF
O
85
86
87