SECTION 5 - BASIC HYDRAULICS INFORMATION & SCHEMATICS
Assembly Instructions for Bulkhead (BH) Fittings
1. Ensure threads and surface are free of rust, weld and
brazing splatter, splits, burrs or other foreign material. If
necessary replace fitting or adapter.
2. Remove the locknut from the bulkhead assembly.
3. Insert the bulkhead side of the fitting into the panel or
bulkhead bracket opening.
4. Hand thread the locknut onto the bulkhead end of the
fitting body.
5. Torque nut onto fitting per Table 5-10, Bulkhead Fittings
(BH) - INCH and Table 5-11, Bulkhead Fittings (BH) -
METRIC while using the Double Wrench Method.
5-18
3121776