SECTION 3 - CHASSIS & TURNTABLE
SPN
523921
523921
523921
523922
523922
523922
523922
523922
523922
523923
523923
523924
523924
523925
523925
523926
523927
523935
523936
523937
523938
523939
523940
523941
523942
523943
523946
523946
523947
523947
523948
523948
523949
523949
523950
523950
523951
523953
523955
523960
523960
3-44
Table 3-1. Deutz Trouble Codes (TD2.9 L4 Engine)
FMI
0
Burner temperature, temperature above upper shutoff threshold
1
Burner temperature, temperature below lower shutoff threshold
2
Burner temperature sensor; Plausibility Check for burner temperature sensor
Sensor burner temperature; plausibility error
3
Burner shut of valve; short circuit to battery
7
Burner Control; Shut-off Valve - Blocked closed Burner Shut Off Valve; blocked closed
7
Burner Shut Off Valve; blocked open
5
Burner Shut Off Valve; open load
12
Burner Shut Off Valve; power stage over temperature
4
Burner Shut Off Valve; short circuit to ground
3
UB1; Short circuit to battery error of actuator relay 1
4
Short circuit to ground error No detail information
3
UB2; Short circuit to battery error of actuator relay 2
4
UB2; Short circuit to ground actuator relay 2
3
UB3: Short circuit to battery error of actuator relay 3.
4
UB3; Short circuit to ground actuator relay 3
4
UB4; Short circuit to ground actuator relay 4.
3
UB5; Short circuit to battery error of actuator relay 5.
12
Timeout Error of CAN-Transmit-Frame EEC3VOL1; Engine send messages
12
Timeout Error of CAN-Transmit-Frame EEC3VOL2; Engine send messages
9
Timeout DFC for NOxSensGlbReqTx. No detail information
9
Timeout Error (BAM to packet) for CAN-Receive-Frame AT1IGCVol1.
9
Broadcast Announce Message of the calibration message of the upstream catalytic NOx sensor has failed.
9
Timeout Error (PCK2PCK) for CAN-Receive-Frame AT1IGCVol1
9
Timeout Error (BAM to packet) for CAN-Receive-Frame AT1OGCVol2.
9
Calibration message 1 of the after catalyst NOx sensor has failed.
9
Timeout Error (PCK2PCK) for CAN-Receive-Frame AT1OGCVol2.
0
Zerofuel calibration injector 1 (in firing order); maximum value exceeded
1
Zerofuel calibration injector 1 (in firing order); minimum value exceeded
0
Zerofuel calibration injector 2 (in firing order); maximum value exceeded
1
Zerofuel calibration injector 2 (in firing order); minimum value exceeded
0
Zerofuel calibration injector 3 (in firing order); maximum value exceeded
1
Zerofuel calibration injector 3 (in firing order); minimum value exceeded
0
Zerofuel calibration injector 4 (in firing order); maximum value exceeded
1
Zerofuel calibration injector 4 (in firing order); minimum value exceeded
0
Zerofuel calibration injector 5 (in firing order); maximum value exceeded
1
Zerofuel calibration injector 5 (in firing order); minimum value exceeded
0
Zerofuel calibration injector 6 (in firing order); maximum value exceeded
2
Healing takes place if the condition for error detection is not present.
Air temperature monitoring plausibility check array No detail information
2
Healing takes place if the condition for error detection is not present.
Air temperature monitoring plausibility check array No detail information
0
Physical range check high for EGR cooler downstream temperature.
1
Physical range check low for EGR cooler downstream temperature.
Error Identification
3121776