JLG 600SC Service And Maintenance Manual page 93

Table of Contents

Advertisement

SPN
524063
524063
524063
524063
524063
524063
524065
524065
524065
524065
524065
524066
524067
524067
524067
524067
524067
524067
524068
524069
524070
524071
524072
524073
524074
524074
524075
524076
524076
524077
524078
524079
524080
524081
524082
524083
3121776
Table 3-1. Deutz Trouble Codes (TD2.9 L4 Engine)
FMI
4
SCR heater main relay load side (K31) on heating valve (Y31),
Short cut to ground.
5
Relay Urea suction line: broken wiring detected (open load) Row engine:
SCR suction line (K28)
V-engine: Master: common SCR-suction line (K28) 
Slave: common SCR back flow line (K29)
5
SCR heater supply module; open load
5
SCR heater tank; open load
12
DEF supply module, time for defrosting too long
12
DEF tank, time for defrosting too long
0
Pressure sensor upstream SCR-CAT, pressure above upper physical threshold
1
Pressure sensor upstream SCR-CAT, pressure below lower physical threshold
3
Pressure sensor upstream SCR-CAT; short circuit battery or open load
4
Pressure sensor upstream SCR-CAT; short circuit ground
2
Pressure sensor upstream SCR-CAT, plausibility error
3
SCR measurement heater output stage; short circuit battery or open load
0
DEF supply module, heater temperature above upper physical threshold
1
DEF supply module, heater temperature below lower physical threshold
0
DEF supply module, temperature above upper physical threshold
1
DEF supply module, temperature below lower physical threshold
2
Supply module heater temperature, plausibility error
2
Supply module temperature, plausibility error
2
Master ECU and Slave ECU have been identified as the same types
9
Timeout Error of CAN-Receive-Frame MSMon_FidFCCTO; Master-Slave CAN communication faulty
2
(Upstream NOx-Sensor) Diagnostic Fault Check for invalid upstream NOx value (Sensor self diagnostic DFC set by Deutz-
SW)
NOx-Sensor before SCR-Cat: Invalid upstream NOx value
2
(Downstream NOx-Sensor) Diagnostic Fault Check for invalid downstream lambda value (Sensor self diagnostic DFC set by
Deutz-SW)
2
(Upstream NOx-Sensor) Diagnostic Fault Check for invalid upstream lambda value (Sensor self diagnostic DFC set by
Deutz-SW)
2
(Downstream NOx-Sensor) Diagnostic Fault Check for invalid downstream NOx value (Sensor self diagnostic DFC set by
Deutz-SW)
9
NOx sensor downstream SCR-CAT, sensor internally open load
2
NOx-Sensor after SCR-Cat: Nox-Sensor dew point problem or plausibility problem
11
NOx sensor downstream SCR-CAT, sensor internally short circuit
9
NOx sensor upstream SCR-CAT, sensor internally open line
2
NOx-Sensor before SCR-Cat: Nox-Sensor dew point problem or plausibility problem
11
NOx sensor upstream SCR-CAT, sensor internally short circuit
9
NOx sensor downstream SCR-CAT, lambda value above upper physical threshold
9
NOx sensor downstream SCR-CAT, lambda value below lower physical threshold
9
NOx sensor upstream SCR-CAT, lambda value above upper physical threshold
9
NOx sensor upstream SCR-CAT, lambda value below lower physical threshold
9
(Downstream NOx-Sensor) Diagnostic Fault Check for downstream NOx value over maximum limit (DFC set by Deutz-SW)
9
NOx-Sensor downstream SCR-CAT, NOx value below minimum value.
SECTION 3 - CHASSIS & TURNTABLE
Error Identification
3-47