SECTION 3 - CHASSIS & TURNTABLE
SPN
1188
1188
1188
1188
1188
1188
1188
1188
1188
1231
1235
1235
1237
1322
1323
1323
1323
1323
1323
1323
1346
1638
1639
1639
1639
1761
1761
1761
1761
1761
1761
1761
1761
2634
2634
2659
2659
2659
2659
2659
2791
2791
3-34
Table 3-1. Deutz Trouble Codes (TD2.9 L4 Engine)
FMI
13
Turbocharger wastegate, EOL calibration error.
12
Turbocharger wastegate, internal electrical error
13
Turbocharger wastegate, learning process aborted.
6
Turbocharger wastegate, current above maximum threshold.
3
Turbocharger wastegate, supply voltage above maximum threshold.
4
Turbocharger wastegate, supply voltage below minimum threshold.
13
Turbocharger wastegate, learning process out of range.
7
Turbocharger wastegate, broken spring detected.
0
Turbocharger wastegate, temperature critical high.
14
CAN-Bus 1 "BusOff-Status"
14
CAN-Bus 2 = CAN_C reports Bus-error (for engines <8L and CV52 it is the engine-CAN@250kbaud) CAN Bus error passive;
warning CAN C - engine CAN
14
CAN-Bus 2 = engine bus "BusOff-Status"
2
Override switch; plausibility error.
12
N/A
12
Too many recognized misfires in cylinder 1 (in firing order)
12
N/A
12
N/A
12
N/A
12
N/A
12
N/A
0
Misfire detection monitoring No detail information
2
Hydraulic oil temperature check for Shut off condition
12
Fan speed sensor; electrical error or signal disturbed or very low fan speed
0
Sensor error fan speed; signal range check high or engine speed respective fan speed too high
1
Sensor error fan speed; signal range check low or fan speed too low
14
DEF tank level; warning threshold exceeded
0
DEF tank, DEF level above upper physical threshold
1
DEF tank, DEF level below lower physical threshold
14
Urea Tank Signal to HMI for indicating the Urea Tank-Level (Urea tank volume ratio low threshold 1)
14
DEF tank, DEF level below first warning threshold
14
DEF tank, DEF level below second warning threshold
2
DEF tank level, plausibility error
14
DEF tank, DEF level below third warning threshold
12
Early opening defect of main relay No detail information
12
DFC for stuck main relay error No detail information
2
Exhaust Gas Recirculation AGS Sensor; signal not plausible
0
Exhaust Gas Recirculation AGS Sensor; Sensed exhaust mass value above maximum physical value
1
Exhaust Gas Recirculation AGS Sensor; Sensed exhaust mass value below minimum physical value
12
Exhaust Gas Recirculation AGS Sensor; plausibility error, AGS sensor has not passed the burn off process
2
Exhaust Gas Recirculation AGS Sensor; Temperature of EGR mass not plausible
12
Actuator EGR Valve; power stage over temperature
7
EGR actuator, actuator blocked
Error Identification
3121776