JLG 600SC Service And Maintenance Manual page 81

Table of Contents

Advertisement

SPN
2791
2791
2791
2791
2791
2791
2791
2791
2791
2791
2791
2797
2797
2798
2798
3031
3031
3031
3219
3224
3224
3224
3224
3224
3226
3227
3234
3234
3234
3234
3234
3241
3248
3251
3251
3251
3251
3253
3253
3253
3253
3361
3121776
Table 3-1. Deutz Trouble Codes (TD2.9 L4 Engine)
FMI
2
EGR actuator, CAN error
13
EGR actuator, EOL calibration error
12
EGR Actuator, internal electrical fault
13
EGR actuator, learning process aborted
6
EGR actuator current is above maximum threshold
3
EGR actuator supply voltage is above the maximum threshold
4
EGR actuator supply voltage is below minimum threshold.
13
EGR actuator, learning process out of range
7
EGR actuator, broken spring detected.
16
EGR actuator, temperature high.
0
EGR actuator, temperature critical high
4
Timeout of Short-Circuit Ground Diagnosis Cyl. Bank 0;_IVDiaShCirGndToutBnk_0
4
Injector diagnostic; Short circuit to ground cylinder bank 0
4
Timeout of Short-Circuit Ground Diagnosis Cyl. Bank 1;_IVDiaShCirGndToutBnk_1
4
Injector diagnostic; Short circuit to ground cylinder bank 1
0
DEF tank, DEF temperature in DEF tank is to high.
1
DEF tank, DEF temperature below lower physical threshold
2
Urea tank temperature outside of plausible thresholds
2
DFC SAE J1939 error No detail information
2
DLC Error of CAN-Receive-Frame AT1IG1 NOX Sensor (SCR-system upstream cat; DPF-system downstream cat); length of
frame incorrect
9
Timeout Error of CAN-Receive-Frame AT1IG1; NOX sensor upstream
2
DLC Error of CAN-Receive-Frame AT1IG1Vol NOX sensor.
9
Timeout Error of CAN-Receive-Frame AT1IG1Vol; NOX sensor.
1
DFC for plausibility error Max for NOx sensor upstream of SCR Cat
2
Nox feed back fault detection No detail information
2
DFC SAE J1939 error No detail information
2
DLC Error of CAN-Receive-Frame AT1O1 No detail information
9
Timeout Error of CAN-Receive-Frame AT1OG1; NOX sensor (SCR-system downstream cat; DPF-system downstream cat)
2
DLC Error of CAN-Receive-Frame AT1O1Vol NOX
9
Timeout Error of CAN-Receive-Frame AT1OG1Vol.
11
DFC for plausibility error Min for NOx sensor downstream of SCR Cat.
0
Sensor SCR catalyst upstream temperature too high; plausibility error.
4
Sensor error particle filter downstream temperature; signal range check low
0
Differential pressure DPF maximum value is exceeded
0
Differential pressure sensor across DPF exceeds warning high limit
1
Differential pressure DPF, pressure below lower shutoff threshold.
1
Differential pressure DPF, pressure below lower warning threshold.
2
Differential pressure DPF, plausibility error
3
Electrical error differential pressure B58 (DPF). (signal range check high)
4
Electrical error differential pressure (DPF). signal range check low.
2
Sensor differential pressure (DPF); plausibility error
7
DEF dosing valve blocked (SCR)
SECTION 3 - CHASSIS & TURNTABLE
Error Identification
3-35

Advertisement

Table of Contents
loading

This manual is also suitable for:

660sjc

Table of Contents