Table 3-1. Deutz Trouble Codes (TD2.9 L4 Engine)
FMI
4
Electrical error charged air temperature. Signal range check low.
Charged air cooler temperature. System reaction initiated. 
0
High charged air cooler temperature. Warning threshold exceeded.
0
High charged air cooler temperature. Shut off threshold exceeded.
Diagnostic fault check for charged air cooler downstream temperature sensor 
11
No detail information
3
Sensor error air filter differential pressure; short circuit to battery
0
Sensor error air filter differential pressure; short circuit to ground
0
Air filter differential pressure; air filter clogged.
11
DFC for CAN message
3
Sensor error ambient air pressure; signal range check high
4
Sensor error ambient air pressure; signal range check low
2
Defect fault check for Absolute plausibility test. No detail information
0
Physical Range Check high for Coolant temperature
1
Physical Range Check low for Coolant temperature.
3
Sensor error coolant temperature; signal range check high
4
Sensor error coolant temperature; signal range check low
0
High coolant temperature; warning threshold exceeded
0
Coolant temperature; system reaction initiated
1
Coolant level too low
1
The air mass flow AFS_dm is greater than or equal to AFS_PhysRng.Min_C
Physical Range Check low for air mass flow sensor. No detail information
0
Rail pressure raw value is intermittent. No detail information
1
Rail pressure raw value is above maximum offset. No detail information
3
Sensor error rail pressure. Sensor voltage above upper limit.
4
Sensor error rail pressure. Sensor voltage below lower limit.
2
Rail pressure safety function is not executed correctly.
3
Sensor error battery voltage; signal range check high.
4
Sensor error battery voltage; signal range check low
2
High battery voltage; warning threshold exceeded
2
High battery voltage; shot off threshold exceeded
0
Physical range check high for battery voltage
1
Physical range check low for battery voltage
0
Environment temperature sensor, temperature above upper physical threshold
1
Environment Temperature Physical Range Check low
3
Sensor error SCR-System environment temperature;
DPF-System air inlet temperature; signal range check high
Sensor error SCR-System environment temperature; 
4
DPF-System air inlet temperature; signal range check low
2
Air inlet filter temperature, plausibility error
3
Air flow temperature sensor; short circuit to battery or open load.
4
Air flow temperature sensor; short circuit to ground
1
Air inlet filter sensor out of physical range check
0
air temperature within air filter box above maximum physical value