Table 3-1. Deutz Trouble Codes (TD2.9 L4 Engine)
FMI
14
Particulate filter regeneration.
Regeneration after time X is not successful (The error occurs when the regeneration times
(3x) over the max. has been aborted allowed recovery time)
5
DPF system; operating voltage error
14
The standstill-regeneration mode time exceeds the long-limit.
Vehicle was too long or too often in standstill mode. Make oil change and reset counter.
14
The standstill-regeneration mode time exceeds the short-limit.
Vehicle was too long or too often within a short time in standstill mode.
Make oil change and reset counter.
8
Max. launch time for stand still exceeded (60min).
2
CAN message PROEGRActr; plausibility error
2
Timeout Error of CAN-Receive-Frame ComEGRActr - exhaust gas recirculation positioner
7
EGR actuator; internal error
13
EGR actuator, calibration error
2
EGR actuator; status message "EGRCust" is missing
7
EGR actuator; due to overload in Save Mode
5
Disc Separator; open load
12
Disc Separator; power stage over temperature
3
Disc separator; short circuit to battery
4
Disc separator; short circuit to ground
12
Injector diagnostics; time out error in the SPI communication
12
Injector diagnostics Slave; time out error in the SPI communication
9
Timeout error of CAN-Receive-Frame ComMS_Sys1TO (error memory Slave); Master-Slave internal CAN message
9
Timeout error of CAN-Receive-Frame ComMS_Sys2TO (error memory Slave); Master-Slave internal CAN message
9
Timeout error of CAN-Receive-Frame ComMS_Sys3TO (error memory Slave); Master-Slave internal CAN message
9
Timeout error of CAN-Receive-Frame ComMS_Sys4TO (error memory Slave); Master-Slave internal CAN message
9
Timeout error of CAN-Receive-Frame ComMS_Sys5TO (error memory Slave); Master-Slave internal CAN message
9
Timeout error of CAN-Receive-Frame ComMS_Sys6TO (error memory Slave); Master-Slave internal CAN message
9
CAN message ComMS_Sys7 not received from slave
9
Master Slave, Error of message counter CAN receive message ComMSMoFOvR; ComMSMoFOvR1CNT
9
Master-Slave CAN; Error Checksum of CAN-Receive Message
9
Master-Slave CAN; Error of message length of CAN receive message ComMSMoFOvR;_ComMSMoFOvR1DLC
9
Timeout error CAN message ComMSMoFOvR1TO error memory Slave
11
Error memory Slave reports FID MSMonFC2 (collective error)
11
Error memory Slave reports FID MSMonFC3 (collective error)
11
Master ECU and Slave ECU data sets or software are not identical
2
Fuel low pressure pump; error pressure build up
2
Particulate filter; regeneration not successful
5
Relay Urea back flow line heater: broken wiring detected (open load)
Row engine: SCR-back flow line (K29)
V-engine: Master: SCR-suction / back flow line (K32.1) 
Slave: SCR-suction / back flow line (K32.2)
5
SCR main relay not connected
5
SCR heater pressure line; open load
3
SCR heater main relay; short circuit to battery
Error Identification