SECTION 3 - CHASSIS & TURNTABLE
SPN
524084
524085
524087
524087
524087
524087
524096
524097
524098
524099
524100
524101
524102
524103
524104
524105
524106
524107
524108
524109
524110
524111
524112
524113
524114
524115
524116
524117
524118
524119
524120
524121
524122
524123
524124
524125
524132
524132
524132
524132
524132
3-48
Table 3-1. Deutz Trouble Codes (TD2.9 L4 Engine)
FMI
9
NOx-Sensor upstream SCR-CAT, NOx value above maximum value.
9
NOx sensor upstream SCR-CAT, NOx value below lower physical threshold
5
Urea Error Lamp; open load
12
Urea Error Lamp; temperature over limit
3
Urea Error Lamp; short circuit battery
4
Urea Error Lamp; short circuit ground
14
Control of the SCR system; If the start stop counter (EPA-Counter) exceeds the threshold
SCRCtl_ctEngStrtStopThresh_C. This counter will increment only once in each driving cycle in case of an SCR error. If the
counter reaches the threshold, the DFC will be set to inhibit the engine start. Engine will not be started, because of EPA-
Counter
9
Timeout error of CAN-Transmit-Frame DPFBrnAirPmpCtl
9
Timeout error of CAN-Transmit-Frame ComDPFBrnPT
9
Timeout error of CAN-Transmit-Frame ComDPFC1
9
Timeout error of CAN-Transmit-Frame ComDPFHisDat.
9
Timeout error of CAN-Transmit-Frame ComDPFTstMon
9
Timeout error of CAN-Receive-Frame ComRxDPFBrnAirPmpCtl
9
Timeout error of CAN-Receive-Frame ComRxDPFBrnAirPmp
9
Timeout error of CAN-Receive-Frame ComRxDPFCtl.
9
Timeout error of CAN-Transmit-Frame ComEGRMsFlw (EGR Steller)
9
Timeout error of CAN-Receive-Frame ComRxEGRMsFlw1 (EGR actuator)
9
Timeout error of CAN-Receive-Frame ComRxEGRMsFlw2 (EGR actuator)
9
Timeout error of CAN-Transmit-Frame ComEGRTVActr (EGR actuator)
9
Timeout error of CAN-Receive-Frame ComRxEGRTVActr (EGR actuator)
9
Timeout error of CAN-Transmit-Frame ComETVActrTO.
9
Timeout error of CAN-Receive-Frame ComRxETVActr
9
Timeout ComIntake Throttle Valve Actr.
9
Timeout error of CAN-Receive-Frame ComRxITVActr
9
Timeout error of CAN-Transmit-Frame A1DOC
9
Timeout error of CAN-Transmit-Frame AT1S
9
Timeout error of CAN-Transmit-Frame SCR2
9
Timeout error of CAN-Transmit-Frame SCR3
9
Timeout error of CAN-Receive-Frame ComRxCM1
9
Timeout error of CAN-Receive-Frame ComRxCustSCR3
9
Timeout error of CAN-Receive-Frame ComRxSCRHtDiag
9
Timeout error of CAN-Receive-Frame ComRxTrbChActr (wastegate actuator)
9
Timeout error of CAN-Receive-Frame ComRxUQSens (Urea quality)
9
Timeout error of CAN-Receive-Frame ComSCRHtCtl
9
Timeout error of CAN-Receive-Frame ComTxAT1IMG
9
Timeout error of CAN-Receive-Frame ComTxTrbChActr (Wastegate actuator)
2
Fuel low pressure upstream fuel low pressure pump not plausible
0
Fuel low pressure upstream fuel low pressure pump, pressure above maximum warning threshold
0
Fuel low pressure upstream fuel low pressure pump, pressure above maximum shut off threshold
1
Fuel low pressure upstream fuel low pressure pump, pressure below minimum shut off threshold
1
Fuel low pressure upstream fuel low pressure pump, pressure below minimum warning threshold