JLG 600SC Service And Maintenance Manual page 106

Table of Contents

Advertisement

SECTION 3 - CHASSIS & TURNTABLE
FAULT
FAULT NO.
GROUP
(IN SERDIA)
50
52
53
Actuator
59
60
62
Hardware 
inputs/ outputs
63
67
68
70
Communication
71
74
3-60
Table 3-2. Deutz Trouble Codes (D2011L04 Engine)
FAULT LOCALITY/
SPN
FAULT DESCRIPTION
Feedback
S ID 24
Reference feedback
S ID 24
Control travel
DI 23
difference
Auto calibration
BOSCH-EDC pumps
S ID 23
faulty operation
Digital output 3
(Switch-off solenoid,
S ID 51
pin M 2)
Digital output 6, pin M
S ID 60
7
Excess voltage switch-
S ID 51
off solenoid
Error Hand Setp1
9 1
Error CAN Step 1
8 9 8
CAN-Bus controller
S ID 231
CAN interface SAE J
S ID 231
1939
Cable break, short
S ID 231
circuit or bus-error
FMI
CAUSE
1 2
Actuator not connected.
Emergency switch-off.
Fault in actuator
Actuator cannot be
confirmation.
operated.
1 3
Injection pump/actuator
jammed or not connected.
Difference between
Fault message (disappears
7
nominal/actual control
when difference is < 10%).
travel is > 10% of the
overall control path.
No automatic actuator
Engine stop / start lock.
equalization possible.
Governor cannot be taken
1 3
Incorrect input of the
into use. EDC actuator
actuator reference values.
calibration required.
2
Driver level is switched off.
Fault (short circuit / cable
break) at digital output.
2
Fault message.
6
1 1
2
CAN-controller for CAN-bus
is faulty. Fault removal
1 2
despite re- initializing
continuously not possible
Application-dependent.
Overflow in input buffer or
9
a transmission cannot be
placed on the bus.
1 4
REMARKS
HELP
Check actuator, replace if required.
Check cable, check fault limits for
"Confirmation".
Check actuator, replace if required.
Check cable, check fault limits for
"Rifeness confirmation".
Check actuator/actuator rods /
injection pump, replace if
required. Check actuator cable.
Check actuator and replaced if
required. Check feedback cable.
Check fault limits and reference
values of the feedback. Program
the fault limits for feedback, save
values. Switch ignition off and on
again.Check again. If faulty, inform
DEUTZ-Service and carry out
automatic equalization again. Set
fault limits again.
Check cable of digital output (cable
break or short circuit).
Check CAN connection,
terminating resistor (see Chapter
12.4), Check control unit.
Check CAN connection, cable
connection. Check sensor and
replace if required.