SPN
523911
523912
523912
523912
523912
523912
523913
523913
523914
523914
523914
523914
523915
523915
523915
523915
523915
523915
523915
523916
523916
523916
523916
523916
523917
523917
523918
523918
523919
523919
523919
523919
523919
523919
523920
523920
523920
523920
523920
523921
523921
3121776
Table 3-1. Deutz Trouble Codes (TD2.9 L4 Engine)
FMI
11
Burner dosing valve (DV2); short circuit high side power stage
2
Burner dosing valve (DV2) downstream pressure sensor; plausibility error
0
Physical range check high for burner dosing valve (DV2) downstream pressure; shut off regeneration
1
Physical range check low for burner dosing valve (DV2) downstream pressure; shut off regeneration. When burner injector
is actuated, the measured pressure does not rise above ca. 1250mbar abs (expected: ca. 2400mbar).
3
Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range check high
4
@ engines < 4l: Throttle valve error, Open Load or Short cut to Battery, blocked valve or wrong control signal for valve.
@ engines with Burner T4i: Pressure Sensor error after valve (DV2), lower limit reached
3
Sensor error glow plug control diagnostic line voltage; signal range check high
4
Sensor error glow plug control diagnostic line voltage; signal range check low
5
Glow plug control; open load water pump control (PWM)
12
Glow plug control; power stage over temperature
3
Glow plug control; short circuit to battery water pump control (PWM)
4
Glow plug control; short circuit to ground water pump control (PWM)
0
HCI dosing valve (DV1); over current at the end of the injection phase
12
HCI dosing valve (DV1); power stage over temperature
3
HCI dosing valve (DV1); short circuit to battery
3
HCI dosing valve (DV1); short circuit to battery high side
4
HCI dosing valve (DV1); short circuit to ground
11
HCI dosing valve (DV1); short circuit high side power stage
7
HCI dosing valve (DV1); blocked open
2
Sensor HCI dosing valve (DV1) downstream pressure; plausibility error
0
Physical range check high for HCI dosing valve (DV1) downstream pressure; shut off regeneration
1
Physical range check low for HCI dosing valve (DV1) downstream pressure; shut off regeneration
3
Sensor error HCI dosing valve (DV1) downstream pressure; signal range check high
4
Sensor error HCI dosing valve (DV1) downstream pressure; signal range check low
3
Sensor error DV1 & DV2 upstream pressure; signal range check high
4
Sensor error DV1 & DV2 upstream pressure; signal range check low
3
Sensor error DV1 & DV2 upstream temperature; signal range check high
4
Sensor error DV1 & DV2 upstream temperature; signal range check low
2
DPF burner air pump pressure sensor, plausibility error
0
DPF burner air pump pressure sensor, pressure above upper shutoff threshold
1
DPF burner air pump pressure sensor, pressure below lower shutoff threshold
3
DPF burner air pump pressure sensor, short circuit to battery or open load
4
DPF burner air pump pressure sensor, short circuit to ground
2
Sensor air pump air pressure; plausibility error
2
Exhaust gas pressure upstream burner, plausibility error
0
Exhaust gas pressure upstream burner, pressure above upper shutoff threshold
3
Exhaust gas pressure upstream burner, short circuit to battery or open load
4
Exhaust gas pressure upstream burner, short circuit to ground
2
Sensor exhaust gas back pressure burner; plausibility error
3
Sensor error burner temperature; signal range check high
4
Sensor error burner temperature; signal range check low
SECTION 3 - CHASSIS & TURNTABLE