JLG 600SC Service And Maintenance Manual page 107

Table of Contents

Advertisement

FAULT
FAULT NO.
GROUP
(IN SERDIA)
76
Memory
7 7
78
80
83
84
85
Control unit
hardware
86
87
90
Program logic
93
94
NOTE: SID is equal to 512. To get SPN #, add 512 + number. For example, SID 254 would be 512+254 or an SPN of 766.
3121776
Table 3-2. Deutz Trouble Codes (D2011L04 Engine)
FAULT LOCALITY/
SPN
FAULT DESCRIPTION
Parameter
programming (write
S ID 253
EEPROM)
Cyclic program test
S ID 240
Cyclic RAM test
S ID 254
Power supply
S ID 254
(Actuator)
Reference voltage 1
S ID 254
Reference voltage 2
S ID 254
Reference voltage 4
S ID 254
Internal temperature
171
Atmospheric pressure
1 0 8
Parameter fault 
(EEPROM retrieval or
S ID 253
checksum faulty).
Stack overflow
S ID 240
Internal fa u lt
S ID 254
FMI
CAUSE
Fault in parameter
programming in the
1 2
governor fixed value
memory.
Constant monitoring of
program memory shows
Emergency switch-off.
1 2
error (so-called "Flash-
engine cannot be started.
test").
Constant monitoring of
2
working memory shows
error.
Power supply for actuator
Fault message (disappears
2
not in the permissible
when power again in the
range.
normal range).
2
Fault message (disappears
Reference voltage for
when power again in the
2
actuator not in the
normal range). Auxiliary
permissible range.
value 5 V
2
Internal temperature for
Fault message (disappears
12
control unit not in
when power again in the
permissible range.
normal range).
Fault message (disappears
when power again in normal
Atmospheric pressure not
12
range). Atmospheric
in permissible range.
pressure monitoring
function de-activated.
No data found or checksum
of data is faulty (note: fault
2
only occurs during setting
Engine cannot be started.
of parameter / saving or
reset.).
Internal calculation fault 
Emergency switch-off.
2
(so-called "Stack over
Engine cannot be started.
flow" fault).
2
SECTION 3 - CHASSIS & TURNTABLE
REMARKS
Switch ignition off and on again.
Check again. If faulty inform DEUTZ
Service
Note values of parameters (3895
and 3896). Switch ignition off and
on again. Check again. If faulty
inform DEUTZ Service.
Switch ignition off and on again.
Check again. If faulty inform DEUTZ
Service.
Check voltage supply. Switch
ignition off and on again. Check
again. If faulty inform DEUTZ
Service.
Switch ignition off and on again.
Check again. If faulty inform DEUTZ
Service.
Check data for correct settings.
Save parameters. Switch ignition
off and on again. Check again. If
faulty inform DEUTZ Service.
Note parameters (3897 and 3898).
Switch ignition off and on again.
Check again. If faulty inform DEUTZ
Service.
HELP
3-61

Advertisement

Table of Contents
loading

This manual is also suitable for:

660sjc

Table of Contents