Table 3-1. Deutz Trouble Codes (TD2.9 L4 Engine)
FMI
5
Injector 5 (in firing order); interruption of electric connection
3
Injector 5 (in firing order); short circuit
4
High side to low side short circuit in the injector 5 (in firing order)
5
Injector 6 (in firing order); interruption of electric connection
3
Injector 6 (in firing order); short circuit
4
High side to low side short circuit in the injector 6 (in firing order)
11
Cold start device relay error
11
Cold start aid relay open load
3
Starter relay high side. Short circuit to battery.
4
Starter relay high side short circuit to ground.
5
Starter relay low side no load error.
12
Starter relay power stage over temperature.
3
Starter relay low side short circuit to battery.
4
Starter relay low side short circuit to ground.
5
Cold start aid relay open load
12
Cold start aid relay; over temperature error
3
Intake Air Heater Device; Short circuit to battery
4
Air intake heater; Short circuit to ground error for power stage on CJ945.
9
Timeout Error of CAN-Receive-Frame TSC1TE; Set point
5
PWM-Signal Fan, Open load or short-circuit ground
3
PWM-Signal Fan, short-circuit to plus
4
PWM-Signal Fan, open load or short circuit to ground
13
Failure of sensor supply voltage 1.
13
Failure of sensor supply voltage 2.
2
Engine shut off demand ignored
0
Physical range check high for ECU temperature
0
Pressure sensor upstream turbine, Physical Range Check high.
1
Pressure sensor upstream turbine, Physical Range Check low.
3
Pressure sensor upstream turbine, signal range check (SRC) high.
4
Pressure sensor upstream turbine, signal range check (SRC) low.
3
Sensor error exhaust gas temperature upstream turbine; signal range check high
4
Sensor error exhaust gas temperature upstream turbine; signal range check low
0
Physical range check high for exhaust gas temperature upstream turbine
1
Physical range check low for exhaust gas temperature upstream turbine
11
Wastegate actuator; internal error
11
Wastegate actuator; EOL calibration not performed correctly
13
Wastegate actuator calibration deviation too large, re-calibration required
2
Wastegate; status message from ECU missing
7
Wastegate actuator; blocked
11
Wastegate actuator; over temperature (> 135°C)
11
Wastegate actuator; operating voltage error
7
Turbocharger wastegate, mechanical blocking detected.
2
Turbocharger wastegate, CAN Error
SECTION 3 - CHASSIS & TURNTABLE
Error Identification
3-33