8 Applicable Support Software for IO-Link Systems
• Using an NJ/NX-series CPU Unit or NY-series Industrial PC as the Controller
For information on making settings for an NX-type IO-Link Master Unit from Sysmac Studio when
using an NJ/NX-series CPU Unit or NY-series Industrial PC as the controller with EtherNet/IP com-
munications, refer to A-1-2 Using an NJ/NX-series CPU Unit or NY-series Industrial PC with Ether-
Net/IP Communications on page A-8.
Use the Sysmac Studio to set EtherNet/IP tag data links, make NX-type IO-Link Master Unit set-
tings, enter the programs, and make adjustments.
• Using a CJ/CP/CS-series PLC or a Controller from Another Company
For information on making settings for an NX-type IO-Link Master Unit from Sysmac Studio when
using a CJ/CP/CS-series PLC or a controller from another company with EtherNet/IP communica-
tions, refer to A-1-3 Using a CJ/CP/CS-series PLC or a Controller from Another Company with
EtherNet/IP Communications on page A-14.
Controller Communications with NX Bus
This description assumes that the controller is an NX-series CPU Unit.
Use the Sysmac Studio to set CPU Unit I/O allocations, make NX-type IO-Link Master Unit settings,
enter the programs, and make adjustments.
Register the IO-Link Master Unit on the CPU and Expansion Racks Configuration Edit Tab Page.
• NX-type IO-Link Master Unit: Right-click the CPU Rack and select Edit,
and register the NX-type IO-Link Master Unit on the CPU and Expansion Racks Configuration Edit Tab Page.
Set the IO-Link Master Unit parameters (including the IO-Link configuration settings).
• NX-type IO-Link Master Unit: Click the Edit Unit Operation Settings Button,
and use the Edit Unit Operation Settings Tab Page to make the settings.
Perform the following step only if the process input data or process output data from an IO-Link device exceeds 2 bytes:
Change the I/O data size in the IO-Link Master Unit.
NX-type IO-Link Master Unit: Click the Edit I/O Allocation Settings Button,
and use the Edit I/O Allocation Settings Pane to add I/O entries to match the I/O sizes of the IO-Link devices.
Use the I/O Map to assign device variables to the I/O ports
Write the programming for cyclic communications and message communications.
• Cyclic communications: Specify the device variables in ordinary instructions.
• Message communications: Use communication instructions to access the IO-Link Master Unit and IO-Link devices.
Place the Sysmac Studio online and download the settings and programs
for the IO-Link Master Unit.
Place the Sysmac Studio online and use the I/O Map Tab Page or the Watch Tab Page
to check the ON/OFF status of the IO-Link devices.
8-6
Start the Sysmac Studio.
*1
*1
*2
of the IO-Link Master Unit.
NX/GX-series IO-Link System User's Manual (W570)