5 Status and Software Switches Other Than for I/O Data
Setting (= object
name)
IO-
Device ID
Link
Device
Infor-
Vendor ID
mation
*4
Area
Serial Num-
ber
IO-Link Revi-
sion
IO-Link Cycle
Time
IO-Link Input
Data Size
IO-Link Out-
put Data Size
Vendor
Name of the
Last Con-
nected IO-
Link Device
Product
Name of the
Last Con-
nected IO-
Link Device
Vendor
*5
Name
Product
*5
Name
*1.
It indicates the IO-Link total communications lost frames.
*2.
When the maximum value of FF hex is reached, totaling stops at FF hex, and no further retries are counted.
*3.
Replace * with a number between 0 and 7.
*4.
If verification is enabled in the IO-Link Device Verification Setting and a verification error occurs for the
IO-Link revision, only the IO-Link revision is given in the IO-Link Device Information Area.
If verification is enabled in the IO-Link Device Verification Setting and verification errors occur for the de-
vice ID, vendor ID, and serial number, device ID, vendor ID, and IO-Link revision are given in the IO-Link
Device Information Area. The serial number is not given. To obtain the serial number, disable verification in
the IO-Link Device Verification Setting and read the IO-Link Device Information Area.
*5.
These objects are supported in IO-Link Master Unit with the unit version 1.1 or later.
*6.
When an IO-Link device is connected, the vendor name and product name are written. Even if the IO-Link
device is disconnected, its vendor name and product name are retained. This enables you to check the
5-4
Description
The type of IO-Link
0000000
device.
0 hex
The vendor ID of the
0000000
IO-Link device.
0 hex
The serial number of
---
the IO-Link device.
The IO-Link revision
00 hex
of the IO-Link device.
This is the cycle time
00 hex
of IO-Link communi-
cations with the IO-
Link devices.
The size (in bytes) of
00 hex
the process input da-
ta from the IO-Link
device.
The size (in bytes) of
00 hex
the process output
data to the IO-Link
device.
Vendor name of the
---
last-connected IO-
*6
Link device
*5
Product name of the
---
last-connected IO-
*6
Link device
*5
Vendor name of the
---
*7
IO-Link device
Product name of the
---
*7
IO-Link device
Default
Setting range
Index
00000000 to
500A
00FFFFFF
to
hex
500D
hex
00000000 to
0000FFFF hex
16 characters
max.
00 to FF hex
00 to FF hex
00 to FF hex
00 to FF hex
64 characters
max.
64 characters
max.
64 characters
max.
64 characters
max.
NX/GX-series IO-Link System User's Manual (W570)
NX-type IO-
GX-type IO-
Link Master
Link Master
Unit
Unit
Sub-
Subin-
Index
index
dex
01 hex 90*0
04 hex
*3
hex
02 hex
05 hex
05 hex 90*1
None
*3
hex
06 hex 90*0
20 hex
*3
hex
08 hex
22 hex
09 hex
24 hex
0A
25 hex
hex
0C
80*2
None
hex
*3
hex
0D
80*3
None
hex
*3
hex
0E
90*2
None
hex
*3
hex
0F hex 90*3
None
*3
hex

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx seriesNx-ilm400Gx-ilm08c