CROSS SECTION
The construction of the pilot valve is shown in the attached cross section drawing. The casing has
vertical holes in which reducing valves are assembled.
The pressure reducing section is composed of the spool(11), spring(8, 9) for setting secondary
pressure, return spring(4), stopper(7), spring seat(5, 6) and spring seat(10). The spring for setting the
secondary pressure has been generally so preset that the secondary pressure is 5 to
20.5kgf/cm
(Depending on the type). The spool is pushed against the push rod(12, 13) by the return
2
spring.
When the push rod is pushed down by tilting the handle, the spring seat comes down simultaneously
and changes setting of the secondary pressure spring.
1
Case
2
Plug
3
O-ring
4
Spring
5
Spring seat (1, 3)
6
Spring seat (2, 4)
7
Stopper
8
Spring (1, 3)
9
Spring (2, 4)
10 Spring seat
11 Spool
12 Push rod (1, 3)
13 Push rod (2, 4)
14 Plug
15 O-ring
16 Rod seal
17 Plate (A)
18 Bushing
19 Machine screw
20 Joint assembly
21 Swash plate
22 Hex nut
2-65
23 Connector
24 Nut
25 Nut
26 Insert
27 Boot
28 Handle
29 Switch assembly
30 Screw
31 Plate
32 Boot