(2)
Continuous rotating
In case of continuous rotating, the oil passage A is also selected high pressure, however, there is
no oil flow to oil passage C. So, anti cavitation valve has no influence during motor operation.
Distriction "B"
Inlet
(High pressure)
P1
Oil passage "B"
(High pressure)
M1
Motor
Counterbalance valve spool
Distriction "C"
Oil passage "A"
Outlet
(Low pressure)
P2
Spool
Oil passage "C"
(Low pressure)
M2
2-59