GROUP 3 ELECTRICAL SYSTEM

1. WHEN STARTING SWITCH IS TURNED ON, MONITOR PANEL DISPLAY DOES NOT
APPEAR
Before disconnecting the connector, always turn the starting switch OFF.
Before carrying out below procedure, check all the related connectors are properly inserted and
short of fuse No. 2.
After checking, insert the disconnected connectors again immediately unless otherwise specified.
Check voltage
between CN-56
(2) and chassis
Starting switch : ON
Voltage : 10~12.5V
Check voltage
YES
10 ~ 12.5V
NO
0V
CLUSTER
POWER IG(12V)
YES
NO
1
2
3
17
CN-56
5-24
Cause
Remedy
Defective cluster
Replace
Disconnection in
Repair or
wiring harness or
replace
poor contact
(After clean)
between CN-56
(1) and fuse No.2.
FUSE
NO.2
R35Z75TS10