Note that the plated surface of rod
assembly(2) is to be lifted.
reason, do not use a wire sling and
others that may damage it, but use a
strong cloth belt or a rope.
Place the removed rod assembly on a
wooden V-block that is set level.
Cover a V-block with soft rag.
(
(
2)
Remove piston and gland
Remove set screw(19)
Remove piston nut(18).
Since piston nut(18) is tightened to a
high torque, use a hydraulic and power
wrench that utilizers a hydraulic cylinder,
to remove the piston nut(18).
Remove piston assembly(12), back up
ring(17), O-ring(10) and cushion ring
(20).
Remove the gland assembly from rod
assembly(2).
If it is too heavy to move, move it by
striking the flanged part of gland with a
plastic hammer.
Pull it straight with gland assembly lifted
with a crane.
Exercise care so as not to damage the lip
of DU bushing(8) and packing (4,5,6,7,
9,10) by the threads of rod assembly(2).
For this
20
Plastic
hammer
7-122
Wooden block
2
12
16,17
Lift with a crane
Pull straight
R35Z77CY23
19
18
R35Z77CY24
R5577CY35