2.
BATTERY CHARGING WARNING LAMP LIGHTS UP(Starting switch : ON)
Before disconnecting the connector, always turn the starting switch OFF.
Before carrying out below procedure, check all the related connectors are properly inserted.
After checking, insert the disconnected connectors again immediately unless otherwise specified.
Check voltage
YES
between CN-2
(13) and chassis
Check voltage
between alternator
terminal "1" and
chassis
Voltage : 10~12.5V
Engine : Running
NO
Check voltage
YES
NO
Check voltage
YES
between CN-56
(3) and chassis
NO
10 ~ 12.5V
0V
CLUSTER
3
CN-2
CN-56
YES
NO
ALTERNATOR
1
13
2
3
CN-74
5-25
Cause
Remedy
Defective cluster
Replace
Disconnection in
Repair or replace
wiring harness or
(After clean)
poor contact
between CN-56(3)
-CN2(13)
Disconnection in
Repair or replace
wiring harness or
(After clean)
poor contact
between
CN-2(13)-alternator
terminal "1"
Defective alternator
Replace
B+
G
L
~
3
I
P
R35Z75TS11