STANDARDS fOR DRIVE CONTROLLERS
EN 61000-4-5
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement
techniques - Surge immunity test (IEC 61000-4-5); German version EN 61000-4-5
EN 61000-4-6
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement
techniques - Immunity to conducted disturbances, induced by radio-frequency
fields (IEC 61000-4-6); German version EN 61000-4-6
EN 61000-4-34
Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement
techniques - Voltage dips, short interruptions and voltage variations immunity
tests for equipment with mains current more than 16 A per phase (IEC 61000-4-
34); German version EN 61000-4-34
EN 61508-1...7
Functional safety of electrical/electronic/programmable electronic safety-related
systems – Part 1...7 (VDE 0803-1...7, IEC 61508-1...7)
EN 62061
Safety of machinery - functional safety of electrical, electronic and program-
mable electronic safety-related systems (VDE 0113-50, IEC 62061)
EN ISO 13849-1
Safety of machinery - safety-related parts of control systems - Part 1: General
principles for design (ISO 13849-1); German version EN ISO 13849-1

Standards that are used in the environment of the drive controller

DGUV regulation 3
Electrical installations and equipment
DIN IEC 60364-5-54
Low-voltage electrical installations - Part 5-54: Selection and erection of
electrical equipment - Earthing arrangements, protective conductors and protec-
tive bonding conductors (IEC 64/1610/CD)
DIN EN 60939-1
Passive filter units for electromagnetic interference suppression - Part 1:
Generic specification (IEC 60939-1:2010); German version EN 60939-1:2010
DIN VDE 0100-729
Low-voltage electrical installations - Part 7-729: Requirements for special
installations or locations - Operating or maintenance gangways (IEC 60364-7-
729:2007, modified); German implementation HD 60364-7-729:2009
DNVGL-CG-0339
Environmental test specification for electrical, electronic and programmable
equipment and systems
EN 1037
Safety of machinery - Prevention of unexpected start-up; German version EN 1037
EN 12502-1...5
Protection of metallic materials against corrosion - Part 1...5
EN 60204-1
Safety of machinery - electrical equipment of machines Part 1: General require-
ments (VDE 0113-1, IEC 44/709/CDV)
EN 60439-1
Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and
partially type-tested assemblies (IEC 60439-1); German version EN 60439-1
EN 60947-7-1
Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment -
Terminal blocks for copper conductors (IEC 60947-7-1:2009); German version
EN 60947-7-1:2009
EN 60947-8
Low-voltage switchgear and controlgear - Part 8: Control units for built-in
thermal protection (PTC) for rotating electrical machines (IEC 60947-8:2003 +
A1:2006 + A2:2011)
EN 61373
Railway applications - Rolling stock equipment - Shock and vibration tests (IEC
61373); German version EN 61373
EN 61439-1
Low-voltage switchgear and controlgear assemblies - Part 1: General rules (IEC
121B/40/CDV); German version FprEN 61439-1
Germ. Lloyd, 7-2
Envoirmental test specification for electrical, electronic and programmable
equipment and systems (DNVGL Class Guidelines DNVGL-CG-0339)
VGB R 455 P
Water treatment and use of materials in cooling systems