Connection Of A Braking Resistor With Temperature Monitoring In Accordance With Ul; Encoder Interface Connection; Resolver Connection At Keb Motors With Connector X3A - KEB COMBIVERT F5 SERVO Installation Manualline

Hide thumbs Also See for COMBIVERT F5 SERVO:
Table of Contents

Advertisement

3.3.6 Connection of a braking resistor with temperature monitoring in accordance with UL

PA, PB Connection for braking resistor
Technical data (see chapter 2.3)
During clearing of the temperature monitoring the input voltage is switched off
for additional protection in regenerative operation connect the auxiliary contacts 11
and 12 of the line contactor K1 (see 3.3.5)
Braking resistors can develop very high surface temperatures, therefor install as safe-to-
touch as possible.
3.4

Encoder interface connection

The plugs may only be connected / disconnected when the inverter and supply voltage are
disconnected !

3.4.1 Resolver connection at KEB motors with connector X3A

• Max. line length 50 m
7
6
8
12
5
9
11
10
4
1
2
3
Servo motor
Resolver plug
12
N
L
PE
230 or 24 V AC/DC
drive
Housing
SIN -
1
SIN+
10
REF -
5
REF +
7
COS -
2
COS+
11
12
11
K1
OH1
U
OH2
at 24 V AC/DC
check tripping
X1A
N
L
PE
X1B
PA
PA
PB
PB
T1
T 2
Housing
Core color
5 SIN -
red
4 SIN+
blue
6 REF -
yellow
3 REF + green
8 COS - pink
7 COS+
gray
1
8
Socket X3A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A6.f5.s3a-342a

Table of Contents