3.3.6 Connection of a braking resistor with temperature monitoring in accordance with UL
•
PA, PB Connection for braking resistor
•
Technical data (see chapter 2.3)
•
During clearing of the temperature monitoring the input voltage is switched off
•
for additional protection in regenerative operation connect the auxiliary contacts 11
and 12 of the line contactor K1 (see 3.3.5)
Braking resistors can develop very high surface temperatures, therefor install as safe-to-
touch as possible.
3.4
Encoder interface connection
The plugs may only be connected / disconnected when the inverter and supply voltage are
disconnected !
3.4.1 Resolver connection at KEB motors with connector X3A
• Max. line length 50 m
7
6
8
12
5
9
11
10
4
1
2
3
Servo motor
Resolver plug
12
N
L
PE
230 or 24 V AC/DC
drive
Housing
SIN -
1
SIN+
10
REF -
5
REF +
7
COS -
2
COS+
11
12
11
K1
OH1
U
OH2
at 24 V AC/DC
check tripping
X1A
N
L
PE
X1B
PA
PA
PB
PB
T1
T 2
Housing
Core color
5 SIN -
red
4 SIN+
blue
6 REF -
yellow
3 REF + green
8 COS - pink
7 COS+
gray
1
8
Socket X3A