Terminal Block X1B Size 18 / 19; Figure 21: Terminal Block X1B Size 18 / 19 - KEB COMBIVERT P6 Instructions For Use Manual

Installation p6 pitch inverter 18/19/23p6 housing g, r
Hide thumbs Also See for COMBIVERT P6:
Table of Contents

Advertisement

POWER UNIT

5.2 Terminal block X1b size 18 / 19

Terminals
U, V, W
F2, U, V, W
BT+, BT-
Connection for batteries / ultracaps
B+, B-
Output for brake DC 24 V
T1, T2
Input for temperature sensor
Output for high-voltage brake
HB+, HB-
BTM
DC voltage measurement
Terminals
function
Protective earth
PE,
Figure 21:
Terminal block X1B size 18 / 19
Ferrules with plastic collar only up to 10 mm
1)
function
Motor output 3-phase
Connection for DC motor
DC 50...300 V (optional)
Measuring input
Screw
connection
4 x M6
.
2
Cable cross-section
in mm²
0.75...16
1)
0.25...6
Depth of thread
in mm
10
Stripping length
in mm
18
15
Tightening torque
in Nm
4.8
45

Advertisement

Table of Contents
loading

Table of Contents