OVERLOAD fUNCTION

3.3.2 DC motor (19P6 DC)

3.3.2.1 Overload function (OL)

Figure 4:

3.3.2.2 Maximum output voltage

The maximum output voltage depending on the output current is shown in the following
characteristic. The output voltage cannot be higher than 1.3 times of the input voltage U
Figure 5:
34
120
110
100
90
80
70
60
50
40
30
20
10
0
50
60
70
Maximum tripping time depending on the output current at DC motors
600
500
400
300
200
100
0
50
60
70
Output voltage depending on the output current
80
90
100
Output current in A
80
90
100
Output current in A
110
120
.
in
110
120

Advertisement