Electrical Operating Conditions; Device Classification; Electromagnetic Compatibility; Table 5: Device Classification - KEB COMBIVERT P6 Instructions For Use Manual

Installation p6 pitch inverter 18/19/23p6 housing g, r
Hide thumbs Also See for COMBIVERT P6:
Table of Contents

Advertisement

OPERATING CONDITIONS

3.1.4 Electrical operating conditions

3.1.4.1 Device classification
Requirement
Overvoltage category
Pollution degree
Table 5:

Device classification

3.1.4.2 Electromagnetic compatibility

EMC emitted interference
Conducted emissions
Radiated emissions
Immunity
Static discharges
1)
Burst - Ports for process meas-
urement control lines and signal
interfaces
Burst - AC - Power ports
Surge - Power ports
Conducted disturbances, induced
by radio-frequency fields
Electromagnetic fields
Voltage fluctuations/
voltage dips
2)
Frequency changes
2)
Voltage deviations
2)
Voltage unbalance
Table 6:
Electromagnetic compatibility
Unless the drive controller is installed in a closed control cabinet and the electrical connections are not ac-
1)
cessible during operation, additional ESD protection measures are required. Details on request.
The P6 may be operated at the limit values specified here according to the standard. Furthermore, it may
2)
also be operated up to the limits (=>
batteries) is connected.
28
Standard
Class
II
EN 61800-5-1
III
2
EN 60664-1
Standard
EN 61800-3
EN 61800-3
Standard
EN 61000-4-2
EN 61000-4-4
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Standard
EN 61000-4-3
EN 61000-2-1
EN 61000-4-34
EN 61000-2-4
EN 61000-2-4
EN 61000-2-4
„3.2 Electrical
data") especially if an energy storage (ultracapacitors /
Descriptions
Only for the heating circuit
=>
„5.11 Connection of the internal heating"
Non-conductive pollution, occasional conden-
sation when PDS is out of service
Class
Descriptions
C2
C2
Level
Descriptions
8 kV
AD (air discharge)
4 kV
CD (contact discharge)
2 kV
4 kV
1 kV
Phase-phase
2 kV
Phase-ground
10 V
0.15...80 MHz
Safety
10 V/m
20 V/m
80 MHz...1 GHz
3 V/m
10 V/m
1...2 GHz
2...2.7 (6) GHz
1 V/m
5 V/m
-15 %...+10 %
Class 3
≤ 2 %
±10 %
≤ 3 %

Advertisement

Table of Contents
loading

Table of Contents