Diagnostic Interface X6A; Figure 51: Diagnostic Interface X6A; Figure 52: Rs232 Cable For Diagnostic Interface - KEB COMBIVERT P6 Instructions For Use Manual

Installation p6 pitch inverter 18/19/23p6 housing g, r
Hide thumbs Also See for COMBIVERT P6:
Table of Contents

Advertisement

DESCRIPTION Of THE TERMINALS

6.3.4 Diagnostic interface X6A

The socket X6A is a serial RS232/485 interface. It serves for the connection of the con-
trol with a PC or other operating units via the protocol DIN66019II. The control unit has
the node address 0, the drive unit has the node address 1. Alternatively, this interface
can be accessed by the IEC control program as desired, thus providing many different
protocol variants (library "SysCom").
Figure 51:
RS 232 cable 2.8 m
Figure 52:
68
X6A
Name
1
PGM
2
TxD
3
RxD
4
RxD-A
5
RxD-B
6
PGM+
7
DGND
8
TxD-A
9
TxD-B
Housing
GND
Diagnostic interface X6A
1
6
Mat.No:
9
5
0058025-001D
RS232 cable for diagnostic interface
The maximum cable length at X6A must not exceed 30 m.
Description
Don't connect !
Transmission signal RS232
Receive signal RS232
Receive signal RS485 A
Receive signal RS485 B
Don't connect !
Data reference potential
Transmission signal RS485 A
Transmission signal RS485 B
Housing is connected internally
to the drive controller PE.
0058025-001D
Socket D-SUb-9
5
9
6
1

Advertisement

Table of Contents
loading

Table of Contents